Pipeline Improvements for Bell Recharge Project

2 Documents in Project

Summary

SCH Number
2020110246
Lead Agency
Shafter-Wasco Irrigation District
Document Title
Pipeline Improvements for Bell Recharge Project
Document Type
NOD - Notice of Determination
Received
Posted
1/14/2021
Present Land Use
A - Exclusive Agriculture

Document Description
Installation of a new, 1-mile-long, Class 125, 21-inch bi-directional PVC pipe within the Kern County road right-of-way (ROW) along Merced Avenue and Mannel Avenue. The new bi-directional pipeline would connect the north and south systems and facilitate water movement through the District. The pipeline would also connect to three existing turnouts and increase the capacity of an existing pump station (from 3 cfs to 10 cfs) on Beech Avenue.

Contact Information
Dana Munn, General Manager
Shafter-Wasco Irrigation District
Lead/Public Agency
6294 Central Valley Highway
Wasco, CA 93280

Phone : (661) 758-5153
dmunn@swid.org

Shafter-Wasco Irrigation District
Project Applicant

Location

Coordinates
35°31'48.7"N 119°16'9.2"W
Cities
Shafter
Counties
Kern
Cross Streets
Mannel Avenue and Merced Avenue
Zip
93263
Total Acres
n/a
Parcel #
n/a
State Highways
n/a
Railways
n/a
Airports
n/a
Schools
Sequioa Elementary
Waterways
Calloway Canal
Township
n/a
Range
n/a
Section
n/a
Base
n/a

Notice of Determination

Approving Agency
Shafter-Wasco Irrigation District
Approving Agency Role
Lead Agency
Approved On
Final Environmental Document Available at
SWID offices - 6294 Central Valley Highway, Wasco, CA 93280

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Attachments

Notice of Determination
SWID Bell Recharge_NOD_20210114-signed   PDF 611 K

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613. For more information, please visit OPR’s Accessibility Site.

Download CSV New Search Print