DWSRF NOD

8 Documents in Project

Summary

SCH Number
2017082044
Lead Agency
City of Antioch
Document Title
DWSRF NOD
Document Type
NOD - Notice of Determination
Received
Posted
3/26/2021
Document Description
DWSRF Notice of Determination for SRF Financing Project description: The Project includes the development of a six million gallons per day brackish water desalination to allow for year-round use of the Applicant’s raw water intake from the San Joaquin River. The Project will provide the Applicant with the ability to treat brackish raw water at the Antioch Water Treatment Plant. Currently, the Applicant is unableto utilize the intake year-round due to seasonal degradation of raw water quality from high chloride levels. The Project involves construction of a microfiltration/ultrafiltration system for water pretreatment, two-stage reverse osmosis system, raw water pipeline, brine disposal pipeline, and replacement of the existing intake pump station and fish screen. The Project includes the design and construction of the proposed facilities.

Contact Information

Name
Scott Buenting
Agency Name
PE Project Manager
Contact Types
Lead/Public Agency / Project Applicant

Location

Cities
Antioch
Counties
Contra Costa
Other Location Info
Within the cities of Antioch and Pittsburg, Contra Costa County, California 94509. The proposed desalination facility will be located within the fence line of the City of Antioch’s (City) existing Water Treatment Plant at 401 Putnam Street, Antioch, CA, and the pipeline routes will generally follow road rights-of-way. The river intake pump station is located at the City’s marina near McElheny Road and Fulton Shipyard Road.

Notice of Determination

Approving Agency
State Water Resources Control Board Division of Financial Assist
Approving Agency Role
Responsible Agency
Approved On
County Clerk
Contra Costa
Final Environmental Document Available at
Lead Agency

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Attachments

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit OPR’s Accessibility Site.