Pacific Gas & Electrica Company Vaca Dixon-Lakeville (kV) Reconductoring Project; Creek and Tributary Alterations

3 Documents in Project

Summary

SCH Number
2014092051
Lead Agency
State Water Resources Control Board
Document Title
Pacific Gas & Electrica Company Vaca Dixon-Lakeville (kV) Reconductoring Project; Creek and Tributary Alterations
Document Type
NOD - Notice of Determination
Received
Posted
6/9/2016
Present Land Use
Various including industrial, commercial, open space, residential, agricultural, and utility
Document Description
PG&E proposes to replace existing conductors on Vaca Dixon-Lakeville 230 kV electric transmission line (Line) with conductors that have a higher emergency rating. PG&E proposes to add 700 megawatts of capacity. The project includes modifications to approx. 189 existing steel lattice towers along the 40-mile Line. At some sites where existing access roads cross drainages, creeks, or other water features, the project will require crossing improvements. Installation of new culverts, replacement of existing culverts, and addition of rock, riprap, or fill (dirt and/or gravel), will be conducted to allow for the passage of construction equipment. Nineteen of the twenty sites that will affect watercourses will consist of temporary or permanent drainage crossing improvements. Depending on site-specific conditions and construction access needs, the drainage crossing improvements will consist of culvert replacement/installation/reinforcement, temporary bridge installation, or at-grade crossing installation. CDFW is executing a Lake and Streambed Alteration Agreement No. 1600-2014-0270-R3 pursuant to Section 1602 of the Fish and Game Code to the project Applicant, Robert Stiving, PG&E.

Contact Information

Name
Joanna Jensen
Agency Name
State Water Resources Control Board
Contact Types
Lead/Public Agency

Location

Cities
Napa, Petaluma, Sonoma, Vacaville
Counties
Napa, Solano, Sonoma
Cross Streets
Various
Zip
Various
Total Acres
506.61
Parcel #
0133-060-070
State Highways
Hwy 116, 121, 12, and 29
Railways
4
Airports
5
Schools
38
Waterways
33 plus associated tributaries
Township
6N
Range
1W
Section
1
Base
MDB&M

Notice of Determination

Approving Agency
CDFW
Approving Agency Role
Responsible Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
N/A
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
N/A
(6) Findings were made pursuant to the provisions of CEQA
N/A

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.