Well 28 Replacement

2 Documents in Project

Summary

SCH Number
2014068183
Public Agency
Eastern Municipal Water District (EMWD)
Document Title
Well 28 Replacement
Document Type
NOE - Notice of Exemption
Received
Posted
6/11/2014
Document Description
Existing Well No. 28 (Peacock and Radaker) is within the San Jacinto Upper Pressure Groundwater Management Zone and is located at 1930 East Mountain Avenue between Esplanade and Hemet Street in the City of San Jacinto. The proposed potable water Well No. 38 is the replacement for this well and is planned to be situated within the existing well site (approximately 3.5 acres). With recent collapse of this existing well, a replacement well is needed as soon as possible to provide critical local water supply and drought tolerance to the surrounding communities in the east valley area of the District. The existing well was designed as a deep well, approximately 1,500 feet, and at design capacity of 2,600 gallons per minute (gpm). The existing well (initially installed in December 1993) was equipped with a 9-stage, oil-lubricated Peerless 8LB vertical turbine pump drive by a 500-hp (initially 350-hp) electric motor. The wellhead and motor were housed inside a masonry building. The well operated at a discharge pressure ranging from 70-90 pounds per square inch (psi) into the adjacent 1,807-ft pressure zone. Over the past several years, the well production has declined from the intimal design capacity to approximately 1,000 gpm due to various reasons including declining water levels (Initial operation: 311-ft below ground surface (bgs) and prior to collapse: 534-ft bgs). In February 2012, the well collapsed and could not be recovered. Since, staff has removed the pump motor and capped the well head to prevent contamination and for safety.

Contact Information

Name
Helen Stratton
Agency Name
Eastern Municipal Water District
Contact Types
Lead/Public Agency

Location

Cities
San Jacinto
Counties
Riverside

Notice of Exemption

Exempt Status
Categorical Exemption
Type, Section or Code
S:15302, Class 2
Reasons for Exemption
Project replaces an existing Well that has collapsed with a new Well that will not increase original capacity. This project meets the criteria for the replacement or reconstruction of existing utility under the categorical exemption provided for within CEQA Guidelines §15302.

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print