Avenue 60 Domestic Water Transmission Main

2 Documents in Project

Summary

SCH Number
2012011033
Lead Agency
Coachella Valley Water District (CVWD)
Document Title
Avenue 60 Domestic Water Transmission Main
Document Type
NOD - Notice of Determination
Received
Posted
3/5/2012
Present Land Use
Agriculture, Rural Residential
Document Description
The Avenue 60 Domestic Water Transmission Main project proposes the construction of approximately 10,000 feet of open trench and 1,350 feet of subsurface boring (using both directional boring and "jack and bore" methods) for a 24-inch domestic water pipeline along Avenue 60 between Polk Street and Pierce Street. Most of the pipeline will be constructed within the Avenue 60 right-of-way; subsurface boring will take place beneath the Coachella Valley Stormwater Channel (CVSC), Hwy 111, UPRR and 86S Expressway. The pipeline will connect the existing domestic water system downstream of the booster pumping station located on the Ion Exchange Treatment Plant No. 6806 (IXTP) site at the project's eastern terminus. A pressure reducing valve will be installed on the IXTP site where the pipeline connects to the existing domestic water system. The purpose of this project is to provide a more reliable domestic water service to existing and future CVWD customers in the Mecca, North Shore, and Area 23 pressure zones. This connection provides a redundant water supply to CVWD's eastern most customers and will reduce the demands on the IXTP for domestic water. In addition, the installation of the water transmission pipeline will allow CVWD to expand its domestic water service east of Polk Street and south of Airport Boulevard, providing existing and future domestic water customers with a reliable water source.

Contact Information

Name
Steve Robbins
Agency Name
Coachella Valley Water District
Contact Types
Lead/Public Agency

Location

Counties
Riverside
Cross Streets
Avenue 60-Polk Street to Pierce Street
Zip
92274
Total Acres
.5
Parcel #
Various
State Highways
Hwy 86, 86S, 111, 195
Railways
UPRR
Airports
Thermal
Waterways
Coachella Valley Stormwater Channel
Township
6S
Range
8E
Section
26-27
Base
SBB&M
Other Location Info
City/Nearest Community: Thermal

Notice of Determination

Approving Agency
Board of Directors of the Coachella Valley Water District
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
N/A
(6) Findings were made pursuant to the provisions of CEQA
N/A

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.