Removal Action Workplan (RAW), Fresno M-4 Elementary School Site (Site Code 104673)

3 Documents in Project

Summary

SCH Number
2010051030
Lead Agency
Fresno Unified School District
Document Title
Removal Action Workplan (RAW), Fresno M-4 Elementary School Site (Site Code 104673)
Document Type
NOD - Notice of Determination
Received
Posted
6/29/2011
Document Description
The RAW specifies removal action objectives, evaluates alternatives, and describes the preferred alternative proposed for cleanup of lead, organ chlorine pesticides (OCP), and waste motor oil in shallow soil at the site. The objective of the RAW is to mitigate potential risk to human health and the environment by reducing or eliminating future exposure to chlordane and dieldrin (chlorinated pesticides used for termite control), lead (from lead-based paint) and waste motor oil in shallow soil identified at several locations within the site. Major elements of the removal action include (1) excavation of ~2,525 cubic yards of contaminated soil; (2) transportation of 140 to 150 truckloads of contaminated soil to permitted waste facilities; and (3) backfilling the excavations with clean soil derived from on-site sources. As required by Health and Safety Code Section 253456.1 (e)(1), a 30-day public comment period for the RAW was held from May 18, 2011 through June 17, 2009. No public comments were received. DTSC approved the RAW as final on June 20, 2011.

Contact Information

Name
Juan Koponen
Agency Name
DTSC
Contact Types
Lead/Public Agency

Location

Cities
Fresno, La Jolla
Counties
Fresno, San Diego
Cross Streets
West side of S. Cedar Ave between E. Heaton and E. Hamilton Aves
Zip
93702
Total Acres
8.43
Parcel #
multiple
State Highways
180
Railways
SJV
Schools
Sequoia MS, Winchell
Township
14S
Range
20E
Section
11
Base
MDB&M

Notice of Determination

Approving Agency
DTSC
Approving Agency Role
Responsible Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
No
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print