Manzanita Elementary School Well Replacement Project

2 Documents in Project

Summary

SCH Number
2025010817
Lead Agency
Manzanita Elementary School District
Document Title
Manzanita Elementary School Well Replacement Project
Document Type
NOD - Notice of Determination
Received
Posted
5/23/2025
Document Description
Well Replacement Project (Project) to construct a new 550-foot-deep well to supply 200 gallons per minute (gpm) of potable water to the school. The Project also includes the demolition of the existing onsite well per Butte County standards, the installation of 900 feet of C-900 polyvinyl chloride (PVC) piping and PVC underground electrical conduit from the new well location to the existing well location. a new 50 kW 240V 3-Phase diesel generator wilh automatic transfer switch on a concrete slab next to the new well, a 6-foot-high chain link fence with privacy slats installed around the well and generator, and a 15,000 square foot access road. The access road will connect the new well site to Center Avenue, located north of the Project Area. A roadside swale will also be constructed to allow for drainage.

Contact Information

Name
Joe Lodigiani
Agency Name
Manzanita Elementary School District
Job Title
Superintendent
Contact Types
Lead/Public Agency / Project Applicant

Location

Cities
Gridley
Counties
Butte
Regions
Northern California
Cross Streets
Evans Reimer Road and Larkin Road
Zip
95948
Total Acres
0.84
Parcel #
024-120-026-000, 024-120-035-000, 024-120-059-000
State Highways
99
Schools
Manzanita Elementary
Waterways
Feather River
Township
187N
Range
03E
Section
00
Base
MDM

Notice of Determination

Approving Agency
Manzanita Elementary School District
Approving Agency Role
Lead Agency
Approved On
County Clerk
Butte
Final Environmental Document Available at
627 E. Evans Reimer Road, Gridley, CA 95948

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
No
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Attachments

Disclaimer: The Governor’s Office of Land Use and Climate Innovation (LCI) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit LCI’s Accessibility Site.