Pump Station 1 Improvements and Modernization

Summary

SCH Number
2024100711
Public Agency
City of San Diego
Document Title
Pump Station 1 Improvements and Modernization
Document Type
NOE - Notice of Exemption
Received
Posted
10/17/2024
Document Description
The project Involves the design contract and scope of work for improvements at Pump Station No. 1. The scope of work Includes upgrading the mechanical screens, rehabilitating the wet wells, replacing the six (6) pumps and rotating assemblies, replacing the motors to work with associated variable frequency drives (VFDs), replacing existing motor starters and liquid rheostats with VFDs, replacement of all suction pipes, replacement of the six 48" suction gate valves, replacement of the six 36" discharge gate valves, replacement of the 30" pump cone valve actuator system, removing the venturl flow meters and replacement with new modern flow meters on the new discharge piping, The work will occur within the Pump Station No, 1 footprint-and will nnot Include soil disturbance.

Contact Information

Name
Scott Vurbeff
Agency Name
City of San Diego, Engineering and Capital Projects
Job Title
Senior Planner
Contact Types
Lead/Public Agency

Location

Cities
San Diego
Counties
San Diego
Regions
Citywide
Other Location Info
The project Is located at 3550 Harbor Drive, San Diego, CA 92101, within the Barrio Logan Communlty Planning Area (Council District 8).

Notice of Exemption

Exempt Status
Categorical Exemption
Type, Section or Code
Sections 15301 (Existing Facilities), 15302 (Replacement or Reconstruction)
Reasons for Exemption
The City of San Diego conducted an environmental review which determined that the project meets the categorical exemption criteria set forth in CEQA State Guidelines, Section 15301 (Existing Facilities), which allows for the minor alteration of existing public structures, involving negligible or no expansion of use beyond that existing at the time of the lead agency's determination, such as rehabilitating the wet wells; Section 15302 (Replacement or Reconstruction), which allows for the replacement or reconstruction of existing structures and facilities where the new structure will be located on the same site as the structure replaced and w/11h ave substantially the same purpose and capacity as the structure replaced, such as replacement of existing motor starters and liquid rheostats, suction gate valves, and suction pipes; and where the exceptions listed in Section 15300.2 would not apply. R-315816
County Clerk
San Diego

Attachments

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit OPR’s Accessibility Site.

Download CSV New Search Print