Permit No. 19740 – Union Pacific Railroad Bridge 101.25 Sacramento Subdivision Bridge Replacement Project
Summary
SCH Number
2024091187
Public Agency
Central Valley Flood Protection Board
Document Title
Permit No. 19740 – Union Pacific Railroad Bridge 101.25 Sacramento Subdivision Bridge Replacement Project
Document Type
NOE - Notice of Exemption
Received
Posted
9/30/2024
Document Description
To replace the existing Union Pacific Railroad Bridge at Mile Post 101.25, Sacramento Subdivision, that crosses Pixley Slough. The existing bridge is a 3-span timber stringer ballast deck (TST-BD) bridge, 43-feet-long with a 16-foot-wide deck. The proposed replacement bridge is a single span, 52-feet-long with a 17-foot-wide deck, 42-inch-deep prestressed concrete box bridge, with erosion control riprap at the abutments.
Contact Information
Name
Jennifer Calles
Agency Name
Central Valley Flood Protection Board
Job Title
Senior Environmental Scientist
Contact Types
Lead/Public Agency
Phone
Location
Counties
San Joaquin
Regions
Northern California
Other Location Info
The project is located at Milepost (MP) 101.25 on Union Pacific Railroad’s Sacramento Subdivision just north of the City of Stockton, where the existing line spans Pixley Slough, approximately 130-feet downstream from the Eight Mile Road bridge, in San Joaquin.
Notice of Exemption
Exempt Status
Categorical Exemption
Type, Section or Code
Sec. 15301 Existing Facilities and Section 15302 Replacement or Reconstruction
Reasons for Exemption
The project is exempt from CEQA under the Class 1, Existing Facilities categorical exemption (CEQA California Code of Regulations, Title 14, Section 15301), because the activity consists of the operation, repair, maintenance, permitting, leasing, licensing or minor alteration of existing public or private structures, facilities, mechanical equipment, or topographical features, involving negligible or no expansion of use. No expansion of existing or former use will occur. In addition, the project is exempt from CEQA under the Class 2, Replacement or Reconstruction categorical exemption (CEQA California Code of Regulations, Title 14, 15302), because the activity consists of replacement and reconstruction of an existing structure in the same site and will have substantially the same purpose and capacity as the replaced structure. Further, none of the exceptions to the exemption in CEQA California Code of Regulations, Title 14, Section 15300.2 apply.
County Clerk
San Joaquin
Attachments
Notice of Exemption
Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit OPR’s Accessibility Site.