Groundwater Recharge Capacity Expansion Project - Ferro Recharge

2 Documents in Project

Summary

SCH Number
2024071176
Lead Agency
United Water Conservation District
Document Title
Groundwater Recharge Capacity Expansion Project - Ferro Recharge
Document Type
NOD - Notice of Determination
Received
Posted
10/10/2024
Document Description
United Water Conservation District (United) operates and maintains approximately 600 acres of groundwater recharge basins, which are used to percolate water and recharge groundwater supplies with Santa Clara River water diverted at the Freeman Diversion. In previous years when conditions were dry with less precipitation, United did not have a need for additional groundwater recharge capacity as its current basins were sufficient to recharge the allowable amount of water United is permitted to divert from the Santa Clara River. However, with wetter conditions and above average precipitation occurring over the last two years, an opportunity exists to recharge additional surface water within the allowable diversion amounts. The Noble Basin and Ferro Basin, located along Vineyard Avenue, are among the groundwater recharge basins United operates. The Ferro Basin is not currently connected to United’s diversion and recharge infrastructure and, as such, cannot be used for artificial groundwater recharge. United proposes to construct an undercrossing beneath Vineyard Avenue and install pipelines to connect the Ferro Basin to the Noble Basin, which would enable the conveyance of water to the Ferro Basin for artificial groundwater recharge. United estimates connecting the basins would, on average over time, provide capacity for an additional 2,000 to 3,000 acre-feet of groundwater recharge per year. Project construction would occur over approximately six to eight months, and would start as early as July 2025; however, in the event of project delays, United would delay construction to begin as late as June 2027. Construction activities would generally occur from 6:30 a.m. to 6:30 p.m., Monday through Friday; trenchless pipeline installation may require constant (24 hours a day, 7 days a week) construction activities. The proposed pipeline would be installed via open cut trench on either side of Vineyard Avenue, and via trenchless methods underneath Vineyard Avenue in accordance with California Department of Transportation requirements. The project would also involve grading and contouring of the embankments along the pipeline alignment and in the Ferro Basin to facilitate recharge.

Contact Information

Name
Hannah Garcia-Wickstrum
Agency Name
United Water Conservation District
Job Title
Environmental Scientist
Contact Types
Lead/Public Agency

Location

Cities
Oxnard, Saticoy
Counties
Ventura
Regions
Countywide
Cross Streets
Vineyard Avenue (State Route 232), Los Angeles Avenue (State Route 118)
Zip
93036
Total Acres
212
Parcel #
Multiple
State Highways
232, 118
Railways
N/A
Airports
N/A
Schools
N/A
Waterways
Santa Clara River
Township
2N
Range
22
Section
00

Notice of Determination

Approving Agency
United Water Conservation District
Approving Agency Role
Lead Agency
Approved On
County Clerk
Ventura
Final Environmental Document Available at
https://www.unitedwater.org/key-documents/#ceqa or United’s offices at 1701 North Lombard Street, Suite 200, Oxnard, California 93030

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Attachments

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit OPR’s Accessibility Site.

Download CSV New Search Print