Adelanto-Toluca Transmission Line 1 Reconductoring Project

Summary

SCH Number
2024010026
Public Agency
Los Angeles Department of Water and Power
Document Title
Adelanto-Toluca Transmission Line 1 Reconductoring Project
Document Type
NOE - Notice of Exemption
Received
Posted
1/3/2024
Document Description
The proposed project consists of repairing a portion of the Adelanto-Toluca (ADL-TOL) Line 1 Transmission Line between transmission towers 45-5 and 50-2 due to the 2009 Station Fire. Maintenance and repair activities include replacing an approximate 4-mile span of damaged conductors, modifying three transmission towers by converting the suspension type arms to dead-end type arms, patching portions of the conductors with minor damage, replacing damaged insulators, and maintaining the transmission line access road (Forest Road 4N32) to enable access for the construction equipment and vehicles. LADWP will require several staging and work areas to place equipment to be used by crews as described below: • 80’ x 100’ tensioner staging area located near Tower 45-5. • 340’ x 180‘tensioner staging area located between tower 45-5 and 46-1 • 40’ x 100’ pull site located on the north side of Tower 47-4. • 30’ x 100’ tensioner staging area located 125 feet northeast of Tower 47-6. • 80’ x 100’ pull site located 400 feet southwest of Tower 49-1. • 80’ x 80’ work site staging area at Tower 49-4.

Contact Information

Name
Aiden Leong
Agency Name
Los Angeles Department of Water and Power
Job Title
Environmental Engineering Associate
Contact Types
Lead/Public Agency / Project Applicant / Parties Undertaking Project

Location

Counties
Los Angeles
Regions
Unincorporated
Cross Streets
Forest Road 4N32, Forest Road 4N35
Zip
91390
Total Acres
28
Parcel #
3209-025-309, 3209-023-306, 3209-023-305, 3209-023-302, 3209-026-307
Township
4N
Range
12W
Section
8

Notice of Exemption

Exempt Status
Categorical Exemption
Type, Section or Code
Class 1 and Class 2, California Code of Regulations, title 14, sections 15301 and 15302;
Reasons for Exemption
In accordance with the California Environmental Quality Act (CEQA), this project is Categorically Exempt from CEQA review pursuant to section 15301 (Existing Facilities) and 15302 (Replacement or Reconstruction). Section 15301, Class 1 consists of the operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing public or private structures, facilities, mechanical equipment, or topographical features, involving negligible or no expansion of the existing or former use. Section 15302, Class 2 consists of replacement or reconstruction of existing structures and facilities where the new structure will be located on the same site as the structure replaced and will have substantially the same purpose and capacity as the structure replaced, including the replacement or reconstruction of existing utility systems/facilities involving negligible or no expansion of capacity. The proposal for the Adelanto-Toluca Transmission Line 1 Reconductoring Project meets the requirements of these exemptions; therefore, no further CEQA review is required.
County Clerk
Los Angeles

Attachments

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613. For more information, please visit OPR’s Accessibility Site.

Download CSV New Search Print