Arlington Mixed Use Development Project - Planning Case PR-2022-001252 - (DP-2022-00035 (General Plan Amendment),
4 Documents in Project
Summary
SCH Number
2023060428
Lead Agency
City of Riverside
Document Title
Arlington Mixed Use Development Project - Planning Case PR-2022-001252 - (DP-2022-00035 (General Plan Amendment),
Document Type
NOD - Notice of Determination
Received
Posted
9/19/2024
Document Description
[PROJECT TITLE CONTINUED:] DP-2022-00036 (Rezone), DP-2022-00025 (Site Plan Review), SD-2022-00002 (Tentative Parcel Map), DP-2022-00047 (Certificate of Appropriateness) and DP-2022-00048 (Certify Environmental Impact Report))
The Project proposes the demolition of the existing vacant 192,139 square foot (sf) former Sears buildings and appurtenances. The 178,426 sf Sears retail structure (consists of a 90,526 sf basement and 87,900 sf ground level) and 13,713 sf auto center structure. The Project proposes the development of approximately 576,203 sf of residential and commercial-retail uses. The residential component of the proposed Project includes development of 27 residential buildings providing for 546,474 sf of residential uses and 4,409 sf Clubhouse/Fitness/Leasing building. The Clubhouse/Fitness/Leasing building will be publicly accessible while the residential portion will be accessible via gates. The residential building component of the project includes 388 dwelling units proposed to be divided between 13 3-story garden style buildings providing for 318 dwelling units and 14 2-story townhome buildings providing for 70 dwelling units. The proposed Project will also provide 25,320 sf of commercial-retail use by way of two commercial-retail buildings in the southeastern portion of the site along Arlington Avenue. A 5,000 sf multi-tenant speculative retail building would be located in the southern corner of the project site with an adjoining outdoor dining/flex space that could include a 24-hour operation. This area of the site also proposes a 20,320 sf grocery store pad. The Project will include several amenities including: onsite leasing office, tuck-under garages, carports, public dog park, outdoor resort style pool and spa, fitness area, clubhouse, shade structures with barbeques and tables, multi-use turf areas, outdoor gaming and play spaces, enhanced pedestrian connectivity, and outdoor gathering areas.
Construction of the Project will occur in two phases, with the first phase being the commercial parcel, and the second phase being the residential parcel, over the course of approximately 23 months. The earthwork is anticipated to include 18,376 cubic yards (CY) of cut and 18,127 CY of fill. This activity results in a net export of approximately 249 CY.
As the Project is an existing developed site with existing vacant structures, utilities are provided within and around the site. Several of the existing utility facilities on-site will be removed and replaced or relocated to provide connection to existing facilities within the rights-of-way. Riverside Public Utilities (RPU) provides electrical services to the Project site. All electrical facilities would connect to existing connections in Arlington Avenue and Streeter Avenue. An additional circuit will be required to meet the Project’s estimated electric demand. This will require approximately 1.5 miles of offsite trenching to connect to existing RPU electric facilities. Trenching will occur within the existing ROW and will include approximately 0.50 miles in Streeter Avenue from Arlington Avenue to Central Avenue; approximately 0.50 miles in Central Avenue from Streeter Avenue to Hillside Avenue; and approximately 0.50 miles in Hillside Avenue Central Avenue to Mountain View Avenue. It is anticipated that trenching may be as deep as 7 to 8 feet below ground. There are some existing conduit and vaults within this alignment. The Project will be required to provide areas of new 6.5-inch conduit and approximately 10 electric vaults sized at 8 feet by 14 feet in order to provide additional circuits and connect to existing facilities.
Implementation of the proposed project requires the following discretionary approvals:
- Environmental Impact Report (EIR)
- General Plan Amendment (GPA): To amend the general plan land use designation from C - Commercial to MU-V - Mixed Use-Village.
- Rezone (RZ): To rezone the site from CG - Commercial General to MU- V - Mixed Use-Village.
- Site Plan Review (PPE): To develop the 17.37 net acre site with a 576,203 square foot (sf) mixed-use apartment community and retail/commercial.
- Tentative Parcel Map No. 38638 (TPM): To subdivide the 17.37 net acre site into 2 parcels for financing, conveyance, and phasing purposes.
- Certificate of Appropriateness (COA): To demolish the existing vacant Sears structures, which have been found to be eligible for listing as a historical resource.
- Overrule of Riverside County Airport Land Use Commission determination of Inconsistency: To overrule the Riverside County Airport Land Use Commission’s January 12, 2023 Inconsistency Determination to the 2005 Riverside Municipal Airport Land Use Compatibility Plan, pursuant to Public Utilities Code Section 21670.
Contact Information
Name
Brian Norton
Agency Name
City of Riverside
Job Title
Senior Planner
Contact Types
Lead/Public Agency
Phone
Email
Location
Cities
Riverside
Counties
Riverside
Regions
Citywide
Cross Streets
Arlington Avenue and Streeter Avenue
Zip
92506
Total Acres
17.43
Jobs
51
Parcel #
226-180-015-1
State Highways
Route 91
Railways
Metrolink
Airports
Riverside Municipal Airport
Schools
Our Lady of Perpetual Help Catholic School, Sierra Middle School
Waterways
Santa Ana River
Township
2S
Range
5W
Section
33
Base
SBBM
Other Information
5261 Arlington Avenue
Notice of Determination
Approving Agency
City of Riverside
Approving Agency Role
Lead Agency
Approved On
County Clerk
Riverside
Final Environmental Document Available at
City of Riverside, Community Development Department, Planning Divisions 3900 Main Street, Riverside CA, 92522
Determinations
(1) The project will have a significant impact on the environment
Yes
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
Yes
(6) Findings were made pursuant to the provisions of CEQA
Yes
Attachments
Notice of Determination
Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit OPR’s Accessibility Site.