Cathodic Protection System Improvement Project – Schedule A & B

Summary

SCH Number
2022050052
Public Agency
Coachella Valley Water District (CVWD)
Document Title
Cathodic Protection System Improvement Project – Schedule A & B
Document Type
NOE - Notice of Exemption
Received
Posted
5/3/2022
Document Description
CVWD proposes to install cathodic protection to existing infrastructure throughout CVWD’s service area. The cathodic protection upgrades will prevent degradation of existing Domestic water, stormwater, canal irrigation, and sanitation facilities impacted by corrosive soils. These upgrades will take place in two schedules, schedule A and schedule B. Schedule A will consist of the Stormwater Channel Sheet Piling, Canal Structure, Surge Gate, Water Reclamation Plant (WRP) 10, and Interstate 10/ Frank Sinatra projects. Schedule B includes the Bombay Beach Pipeline, Mid-Valley Pipeline, and the Gas Transmission Pipeline project. The Stormwater Channel Sheet Piling component includes restoring AC power to four existing rectifiers, as well as replacing twenty-five deep anodes into wells connected to the rectifier. The Canal Structure project component includes installing and replacing 100 anodes in multiple Mile Post locations. The Mile Post anodes are existing structures along the Coachella Canal. The Surge Gate portion of the project includes installing 20 new anodes throughout the domestic water system. These new installations are on existing gate structures of CVWDs domestic water system. The WRP 10 project component consists of exposing existing test wires and verifying continuity between the wires and existing structures. The project also includes the constructing of an at-grade post-mounted test station enclosure. The Bombay Beach Pipeline component will consist of repairing test station deficiencies as required and performing cycle testing to determine electrical discontinuity. Also, excavating the existing pipeline at each suspected discontinuous pipe joint and installing 2 - #4 AWG joint bond cables across each discontinuous joint. The Interstate 10/Frank Sinatra portion of the project will raise the top of the concrete traffic box to ground elevation at Test Station (TS) 1 and TS 2; and replace the concrete traffic box at TS 3 and install a concrete traffic box at TS 4. The Mid-Valley Pipeline component consists of installing new rectifiers at existing TS 7 and TS 9. Each Rectifier will be installed with a concrete collar. A new 250’ x 10” wide well will be drilled at each rectifier located adjacent to the Stormwater Channel, up to 75 anode, depending on depth, will be placed along the Mid Valley Pipeline and connected to the rectifiers though deep wells. The Gas Transmission Pipeline component consists of installing a new TS and galvanic anode installation.

Contact Information

Name
Dan Charlton
Agency Name
Coachella Valley Water District - Coachella, CA
Job Title
Assistant General Manager - Operations
Contact Types
Lead/Public Agency

Name
William Patterson
Agency Name
Coachella Valley Water District
Job Title
Environmental Supervisor
Contact Types
Lead/Public Agency

Location

Cities
Coachella, Imperial, Palm Desert
Counties
Imperial, Riverside
Regions
Unincorporated
Other Location Info
The Cathodic Protection System Improvement Project will include multiple locations that is broken up between two schedules. Schedule A includes North Shore Sheet Piling, Canal Structure, Surge Gate, Water Reclamation Plant (WRP) 10, and Interstate 10/ Frank Sinatra projects. Schedule B includes the Bombay Beach Pipeline, Mid-Valley Pipeline, and the Gas Transmission Pipeline project. The Stormwater Channel Sheet Piling portion of the project is located north of the Commerce Street and Avenue 45 intersection and travels easterly along the Coachella Valley Stormwater Channel ending near the Avenue 50 intersection in Riverside County (APN 603-020-010, 696-530-008, 603-290-010, 603-300-018). Work is located outside of the Stormwater Channel. The Canal Structure portion of the project will take place throughout the Coachella Canal starting from Mile Post 3.8 (Latitude: 32.762264, Longitude: -114.969617) in Imperial County and ending at Mile Post 123.5 located in Riverside County (Latitude: 33.62785314, Longitude: -116.2687989). The Surge Gate portion of the project will take place at 10 different sites throughout the domestic water system within Riverside County located at Latitude, Longitude: 33.540019, -115.99179; 33.565838, -116.02655; 33.602231, -116.09515; 33.506308, -116.13869; 33.499078, -116.13015; 33.440837, -116.07033; 33.611285, -116.11464; 33.685315, -116.21208; 33.689145, -116.18089; 33.566032, -116.00891. The WRP 10 portion of the project will take place within the WRP 10 boundaries located at 43000 Cook Street in Palm Desert, CA. The Bombay Beach Pipeline potion of the project will have multiple project locations in Riverside County and will start at Latitude, Longitude: 33.53653, -116.015134; and move easterly along Grapefruit Boulevard ending at Latitude, Longitude: 33.356146, -115.742838. The Interstate 10/Frank Sinatra portion of the project is located in two areas. The first is near the intersection of Frank Sinatra Drive and Tamarisk Row Drive. The second site is located north the Frank Sinatra Drive and Tamarisk Row Drive intersection between Varner Road and the Interstate 10 Freeway. Both locations are located in the City of Palm Desert, CA. The Mid-Valley Pipeline portion of the project is located adjacent to the Coachella Valley Stormwater Channel within Riverside County (APN 633-150-032, 604-640-011). The Gas Transmission Pipeline Portion of the project is located near the east end of Coyote Song Way located in Palm Desert, CA.

Notice of Exemption

Exempt Status
Categorical Exemption
Type, Section or Code
15301, 15302 and 15303
Reasons for Exemption
State CEQA Guidelines §15301 (Existing Facilities) allows for the repair and maintenance of existing public structures and facilities involving negligible or no expansion of use. State CEQA Guidelines §15032 (Replacement or Reconstruction) allows for projects consisting of replacement or reconstruction of existing structures and facilities where the new structure will be located on the same site as the structure replaced and will have substantially the same purpose and capacity as the structure replaced. State CEQA Guidelines §15303 (New Construction or Conversion of Small Structures) consists of construction and location of limited numbers of new, small facilities or structures; installation of small new equipment and facilities in small structures; and the conversion of existing small structures from one use to another where only minor modifications are made in the exterior of the structure.

Exempt Status
Other
Type, Section or Code
15061 (b)(3)
Reasons for Exemption
Review for Exemption “Common Sense” Exemption: State CEQA Guideline §15061(b)(3)
County Clerks
Imperial, Riverside

Attachments

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613. For more information, please visit OPR’s Accessibility Site.