Fontaine Pumping Plant Replacement Project

2 Documents in Project

Summary

SCH Number
2021100260
Lead Agency
East Bay Municipal Utility District (EBMUD)
Document Title
Fontaine Pumping Plant Replacement Project
Document Type
NOD - Notice of Determination
Received
Posted
2/23/2022
Document Description
EBMUD’s existing 20 million gallon per day (mgd) Fontaine Pumping Plant (PP), located at 8445 Ney Avenue, Oakland, will be replaced with a new 20 mgd PP and new rate control station (RCS) on EBMUD-owned property at 9601 MacArthur Boulevard, Oakland. Approximately 4,750 feet of new 30-inch suction and discharge pipelines would be constructed to connect the new Fontaine PP and RCS to the distribution system. Upon construction completion and successful testing of the new PP, pipelines and RCS, the existing PP would be demolished and approximately 2,100 feet of existing buried pipelines would be abandoned in place.

Contact Information

Name
Daniel Jones
Agency Name
East Bay Municipal Utility District
Job Title
Associate Civil Engineer
Contact Types
Lead/Public Agency

Location

Cities
Oakland
Counties
Alameda
Regions
Northern California
Other Location Info
City of Oakland, Alameda County (see attached map)

Notice of Determination

Approving Agency
East Bay Municipal Utility District
Approving Agency Role
Lead Agency
Approved On
County Clerk
Alameda
Final Environmental Document Available at
East Bay Municipal Utility District, Office of the Secretary, Room 829, 375 Eleventh Street, Oakland, CA 94607, and on the District website at: and https://www.ebmud.com/FontainePP

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Attachments

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613. For more information, please visit OPR’s Accessibility Site.

Download CSV New Search Print