Vortex Tube Rehabilitation Project NOD

2 Documents in Project

Summary

SCH Number
2020080522
Lead Agency
Sonoma County Water Agency
Document Title
Vortex Tube Rehabilitation Project NOD
Document Type
NOD - Notice of Determination
Received
Posted
11/18/2020
Document Description
The Vortex Tube is part of the Santa Rosa Creek Diversion Structure, a concrete flood control facility constructed in 1963 as part of the Central Sonoma Watershed Project to reduce flooding in downtown Santa Rosa. A concrete culvert beneath Montgomery Drive, known as the Vortex Tube, regulates peak winter floods in Santa Rosa Creek. The Vortex Tube has been damaged by abrasion during high flows. The purpose of the Proposed Project is to extend the useful life of the Vortex Tube by restoring its structural integrity. The Proposed Project’s repair of the Vortex Tube would be implemented in two phases: 1) construct a permanent Bypass Pipe beneath Montgomery Drive to temporarily direct creek flows around the Vortex Tube, and 2) dewater and repair the damaged Vortex Tube. The Proposed Project would not change the function or expand the capacity of the Diversion Structure.

Contact Information

Name
David Cook
Agency Name
Sonoma County Water Agency
Contact Types
Lead/Public Agency

Location

Cities
Santa Rosa
Counties
Sonoma
Other Location Info
The project is located on Santa Rosa Creek where it flows beneath Montgomery Drive, approximately 4 miles east of downtown Santa Rosa and approximately 3/4 mile east of Spring Lake Regional Park in Sonoma County.

Notice of Determination

Approving Agency
Sonoma County Water Agency
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Attachments

Notice of Determination

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613. For more information, please visit OPR’s Accessibility Site.

Download CSV New Search Print