Sailor Bar Pump Station Replacement Project
3 Documents in Project
Download CSV
New Search
Print
Summary
- SCH Number
- 2020049047
- Lead Agency
- Sacramento County
- Document Title
- Sailor Bar Pump Station Replacement Project
- Document Type
- NOD - Notice of Determination
- Received
- Posted
- 8/31/2020
- Document Description
- The Sailor Bar Pump Station Project consists of replacing an existing sanitary sewer pump station with a new pump station and appurtenant facilities. Site improvements will include demolition and replacement of existing pavement and access road, raising the site above the 100-year floodplain, relocating the existing access road, constructing a new electrical building with staff restroom, and installing a perimeter fence. The new pump station will include four new submersible pumps in a 35-ft deep dual wet well, new site piping, new instrumentation, and provisions for future bypass pumping operations. New electrical equipment will be installed in the new electrical building. The existing utility transformer will be replaced with a new unit and relocated. The existing standby generator will be relocated on-site and continue to serve the new pump station facilities. Following completion of the new pump station, the existing pump station will be demolished and existing buried facilities will be abandoned in-place.
- Contact Information
-
Tim Hawkins
Sacramento county planning
Lead/Public Agency
827 7th street ste 225
sacramento, CA 95814
Phone : (916) 874-5909
hawkinst@saccounty.net -
Sacramento Area Sewer District
Project Applicant
Location
- Cities
- Sacramento
- Counties
- Sacramento
- Regions
- Countywide
- Parcel #
- 246-0170-047 and portion of 246-0260-010
Notice of Determination
- Approving Agency
- Sacramento Area Sewer District
- Approving Agency Role
- Lead Agency
- Approved On
- Final Environmental Document Available at
- https://planningdocuments.saccounty.net/
Determinations
- (1) The project will have a significant impact on the environment
- No
- (2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
- No
- (2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
- Yes
- (2c) An other document type was prepared for this project pursuant to the provisions of CEQA
- No
- (3) Mitigated measures were made a condition of the approval of the project
- Yes
- (4) A mitigation reporting or monitoring plan was adopted for this project
- Yes
- (5) A Statement of Overriding Considerations was adopted for this project
- No
- (6) Findings were made pursuant to the provisions of CEQA
- No
Attachments
- Notice of Determination
- NOD PDF 33 K
Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613. For more information, please visit OPR’s Accessibility Site.