Solano 4 Wind Project
8 Documents in Project
Summary
SCH Number
2019012016
Lead Agency
Sacramento Municipal Utility District
Document Title
Solano 4 Wind Project
Document Type
NOD - Notice of Determination
Received
Posted
8/20/2021
Document Description
The Solano 4 Wind Project consists of decommissioning existing wind turbine generators (WTGs) and constructing up to 22 new WTGs in the Solano County Wind Resource Area of Solano County. The Project would have a net energy production capacity of up to 91 MW. Individual WTGs would have a maximum height of 492 to 590 feet and rotor diameter of 446 to 492 feet. Access roads and electrical collection system would be installed to support the new WTGs, along with minor upgrades to the Russel Substation. In approving the Project, SMUD determined there is no feasible alternative (Gov. Code 53096) and the Project is consistent with the purposes of the State Aeronautics Act.
Contact Information
Name
Ammon Rice
Agency Name
Sacramento Municipal Utility District
Contact Types
Lead/Public Agency
Phone
Email
Location
Coordinates
Counties
Solano
Cross Streets
Montezuma Hills Road and Toland Lane
Zip
94571
Total Acres
2,549
Township
03N
Range
02E
Section
9
Other Location Info
1785 Toland Lane, Suisun City, CA 94571
Other Information
Project comprises two distinct geographic sites, Solano 4 East (Lat. 38.123158, Long. -121.767756) and Solano 4 West (Lat. 38.077980, Long. -121.815643)
Notice of Determination
Approving Agency
Unanimous decision by SMUD Board of Directors
Approving Agency Role
Lead Agency
Approved On
County Clerk
Solano
Final Environmental Document Available at
smud.org/CEQA, 6301 S St, Sacramento, CA 95817 or 4401 Bradshaw Rd, Sacramento, CA 95827
Determinations
(1) The project will have a significant impact on the environment
Yes
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
Yes
(6) Findings were made pursuant to the provisions of CEQA
Yes
Attachments
Notice of Determination
Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit OPR’s Accessibility Site.