Feather River Bridge Scour Project
9 Documents in Project
Download CSV
New Search
Print
Summary
- SCH Number
- 2018102014
- Lead Agency
- Caltrans 3 (Marysville) (California Department of Transportation, District 3)
- Document Title
- Feather River Bridge Scour Project
- Document Type
- NOD - Notice of Determination
- Received
- Posted
- 1/22/2019
- Present Land Use
- rural/OS
- Document Description
- Caltrans proposes a scour retrofit project to protect piers of the Feather River Bridge. Specifically, piers 17-20 and 23 will be retrofitted to protect the structural integrity of the bridge, reduce existing critical scour, and prevent future scour. In addition, the rock slope protection placed along the east bank and east floodplain will be removed to ensure the lateral migration of the channel. RSP will also be placed between pier 23 and the west bridge abutment to address potential west levee scour.
- Contact Information
-
Mundeep Purewal
California Department of Transportation, District 3
703 B St
Marysville, CA 95901
Phone : (530) 741-4590
Location
- Cities
- Marysville Yuba City
- Counties
- Sutter Yuba
- Cross Streets
- Feather River (below bridge)
- Zip
- various
- State Highways
- 20, 99
- Schools
- Marysville HS
- Waterways
- Feather River, Ellis Lake, Yuba River
Notice of Determination
- Approving Agency
- Caltrans
- Approving Agency Role
- Lead Agency
- Approved On
- Final Environmental Document Available at
- 703 B Street, Marysville, CA 95901
Determinations
- (1) The project will have a significant impact on the environment
- No
- (2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
- No
- (2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
- Yes
- (2c) An other document type was prepared for this project pursuant to the provisions of CEQA
- No
- (3) Mitigated measures were made a condition of the approval of the project
- Yes
- (4) A mitigation reporting or monitoring plan was adopted for this project
- N/A
- (5) A Statement of Overriding Considerations was adopted for this project
- No
- (6) Findings were made pursuant to the provisions of CEQA
- Yes
Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.