East County Advanced Water Purification Project

6 Documents in Project

Summary

SCH Number
2018091029
Lead Agency
Padre Dam Municipal Water District
Document Title
East County Advanced Water Purification Project
Document Type
NOD - Notice of Determination
Received
Posted
12/7/2018
Present Land Use
Ray Stoyer WRF is designated as public in Santee GP; Z as Park/OS in Santee zoning ordinance
Document Description
The project will create a new local, sustainable, and dorught-proof water supply using state-of-the-art technology. The project proposes to recycle East San Diego COunty's wastewater locally and then purify the water at an Advanced Water Treatmen Plant (AWTP). The purified water would be transported to lake Jennings for surface water augmentation. The proposed project would include upgrades to the existing influent pump station, expansion of the Ray Stoyer Water Recycling Facility to 18 MGD average annual capacity, construction of a Solids Handling and Energy Recovery Facility, construction of an AWTP Facility (11.5 MGD average annual capacity) and construction of facilities to convey purified water from the AWTP Facility to Lake Jennings for surface water augmentation. Additionally, the proposed project includes modifications to the East Mission Gorge Pump Station and construction of a force main, and a residuals bypass system.

Contact Information

Name
Mark Niemiec
Agency Name
Padre Dam Municipal Water District
Contact Types
Lead/Public Agency

Location

Cities
Santee
Counties
San Diego
Cross Streets
Carlton Oaks Dr and Fanita Parkway
Zip
92071
Total Acres
~9
State Highways
SR 125, 67, 52, I-8
Airports
Gillespie Field
Schools
Sycamore Canyon
Waterways
San Diego River
Township
15S
Range
1W
Base
SanVinc
Other Information
Unincorporated of Lakeside

Notice of Determination

Approving Agency
Padre Dam Municipal Water District
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print