Low Flow Efficiency Improvements at Pumping Plant 7-1

Summary

SCH Number
2018031004
Lead Agency
Westlands Water District
Document Title
Low Flow Efficiency Improvements at Pumping Plant 7-1
Document Type
NEG - Negative Declaration
Received
Present Land Use
ae20 - exclusive ag
Document Description
The focus of the Low Flow Efficiency Improvements at Pumping Plant 7-1 is to improve efficiency during conveyance of low flows. Pumping plant 7-1 currently consists of four 25 cfs (11,200 gpm) pumps. Low flow deliveries to lateral 7 are achieved by recirculating pumped water back to the suction side of PP-1, while maintaining 2 cfs flow from the San Luis Canal. Consequently, energy used to pump the recirculated flow is lost across the globe valve. To improve the efficiency for conveying low flows, Westlands proposes to install a new 350 hp low flow pump (2 to 13 cfs), 2300-volt variable frequency drive, switchgear main, metering, and motor control center system to increase the low flow efficiency of PP7-1.

Contact Information

Name
Charlotte Gallock
Agency Name
Westlands Water District
Contact Types
Lead/Public Agency

Location

Cities
Mendota
Counties
Fresno
Cross Streets
Adams and Merced alignment
Zip
93668
Total Acres
0.25
Parcel #
028-030-26ST
State Highways
33
Waterways
Mendota Pool
Township
15S
Range
15E
Section
9
Base
MDBM

Notice of Completion

State Review Period Start
State Review Period End
State Reviewing Agencies
Cal Fire, California Department of Conservation (DOC), California Department of Fish and Wildlife, Central Region 4 (CDFW), California Department of Parks and Recreation, California Department of Transportation, District 6 (DOT), California Highway Patrol, California Native American Heritage Commission (NAHC), California Regional Water Quality Control Board, Central Valley Fresno Region 5 (RWQCB), Central Valley Flood Protection Board, Department of Food and Agriculture (CDFA), Department of Toxic Substances Control, Department of Water Resources, Resources Agency, State Water Resources Control Board, Division of Drinking Water, District 23
Development Types
Water Facilities (Type pumping plant im, MGD 1.1-7)

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.