GWMA Recycled Water Pipelines Project in the City of Lynwood

4 Documents in Project

Summary

SCH Number
2017051049
Lead Agency
Central Basin Municipal Water District
Document Title
GWMA Recycled Water Pipelines Project in the City of Lynwood
Document Type
NOD - Notice of Determination
Received
Posted
4/25/2018
Present Land Use
N/A; Public street ROW
Document Description
The project would include the installation of approx 9,408 lf of recycled water pipeline varying in size from 8-12 in diameter. The proposed recycled water pipeline would connect to Central Basin's 8-in diameter recycled water pipeline at the intersection of Wright Rd and Fernwood Ave. It would extend approx 6,113 lf in an easterly direction along Fernwood Ave to its intersection with Bullis Rd. Approx 2,425 lf of recycled water pipeline would extend along Bullis Rd in a northerly direction to the Lynwood Civic Center Complex. Approx 424 lf of 8-in diameter recycled water pipeline would extend in a southerly direction from Fernwood Ave along Harris Ave and another 435 lf of 8-in diameter recycled water pipeline would extend in a southerly direction from Fernwood Ave along Atlantic Ave. The new recycled water pipeline would serve the new Lynwood Linear Park along Fernwood Ave, the Lynwood City Park and the Lynwood City Hall Complex along Bullis Rd.

Contact Information

Name
Roman C. Gonzalez
Agency Name
Central Basin Municipal Water District
Contact Types
Lead/Public Agency

Location

Cities
Lynwood
Counties
Los Angeles
Cross Streets
Fernwood Ave and Bullis Rd
Zip
90262
State Highways
105, 710
Waterways
Rio Hondo
Base
SBBM

Notice of Determination

Approving Agency
Board of Directors of the Central Basin Municipal Water District
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above.

Download CSV New Search Print