Bridge Seismic Safety Retrofit Project in SAC and San Joaquin Counties, EA# 03-3F090 [California Endangered Species Act (CESA) Incidental Take Permit No. 2081-

10 Documents in Project

Summary

SCH Number
2016072040
Lead Agency
Caltrans 3 (Marysville) (California Department of Transportation, District 3)
Document Title
Bridge Seismic Safety Retrofit Project in SAC and San Joaquin Counties, EA# 03-3F090 [California Endangered Species Act (CESA) Incidental Take Permit No. 2081-
Document Type
NOD - Notice of Determination
Received
Posted
3/29/2019

Document Description
-2018-070-03 (ITP)] The Project is limited to the retrofit of the existing Mokelumne River Bridges (Bridge No. 29-0197L/R) by replacing the existing multi-column bents with new outrigger bents and constructing new bent caps which will support the existing bridge decks. Each of the two bridges is supported by 20 existing bents (40 bents total). Each new outrigger bent will be supported by two new pile shafts comprised of 4-ft (48-inch) diameter cast.in steel shell (CISS) concrete piles (a total of 40 outrigger bents supported by a total of 80 new pile shafts). Once the new outrigger bent systems have been constructed the columns of the existing bents will be removed. *See NOD FOR MORE DETAILS

Contact Information
Robert Stanley
CDFW
2825 Cordelia Road, Suite 100
Fairfield, CA 94534

Phone : (707) 428-2039

Location

Coordinates
38.254958°'"N -121.447751°'"W
Counties
Sacramento San Joaquin
Other Location Info
Mokelumne River Bridge (Bridge No. 29-0197L/R) over the Mokelumne River and the associated floodplain on Interstate 5 (1-5) at Post Mile (PM) 49.78 at the San Joaquin/Sacramento County border

Notice of Determination

Approving Agency
CDFW
Approving Agency Role
Responsible Agency
Approved On
Final Environmental Document Available at
2825 Cordelia Road, Suite 100, Fairfield, CA 94534

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Attachments

Notice of Determination
2016072040 b   PDF 1029 K
Download CSV New Search