Crown Hill Pump - Tank System
2 Documents in Project
Download CSV
New Search
Print
Summary
- SCH Number
- 2015051035
- Lead Agency
- Ventura County Waterworks District 8
- Document Title
- Crown Hill Pump - Tank System
- Document Type
- NOD - Notice of Determination
- Received
- Posted
- 10/5/2015
- Present Land Use
- Vacant / RE-10,000 sf / Existing Community
- Document Description
- The Ventura County Waterworks District No. 8 (District) is proposing the Crown Hill Pump-Tank System Project to provide a higher elevation tank and increase water storage serving the Santa Susana Knolls neighborhood (Knolls). The proposed facilities are: Crown Hill Pump Station - Two pump units, each rated at 300 gpm, 110 feet lift, and 10 horsepower; Crown Hill Tank - One welded-steel tank with a diameter of 72 feet, a height of approximately 36 feet, a storage capacity of 1 million gallons, a high-water elevation (HWE) of 1490 feet, and a pad elevation of 1458 feet; Water Line - 1,100 feet of 8-inch water line; Pressure Reducing Station - An interconnection between the proposed Crown Hill Tank (HWE 1490 feet) and the existing Alta Vista Tanks (HWE 1404 feet) allowing hydraulic interoperability.
- Contact Information
-
Lauren Funaiole
City of Simi Valley
Lead/Public Agency
2929 Tapo Canyon Road
Simi Valley, CA 93063
Phone : (805) 583-6772
Location
- Cities
- Simi Valley
- Counties
- Ventura
- Cross Streets
- Crown Hill Drive, Lyon Place
- Zip
- 93063
- Total Acres
- .86
- Parcel #
- 646-0-161-060; 646-0-161-070
- State Highways
- Hwy 118
- Railways
- UPRR
- Waterways
- Arroyo Simi
- Other Location Info
- Santa Susana Knolls
Notice of Determination
- Approving Agency
- City of Simi Valley
- Approving Agency Role
- Lead Agency
- Approved On
- Final Environmental Document Available at
- 2929 Tapo Canyon Road, Simi Valley, CA 93063
Determinations
- (1) The project will have a significant impact on the environment
- No
- (2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
- No
- (2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
- Yes
- (2c) An other document type was prepared for this project pursuant to the provisions of CEQA
- No
- (3) Mitigated measures were made a condition of the approval of the project
- No
- (4) A mitigation reporting or monitoring plan was adopted for this project
- N/A
- (5) A Statement of Overriding Considerations was adopted for this project
- No
- (6) Findings were made pursuant to the provisions of CEQA
- Yes
Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.