Vaca Valley Parkway / I-505 Southbound Ramp Improvements

2 Documents in Project

Summary

SCH Number
2012032027
Lead Agency
City of Vacaville
Document Title
Vaca Valley Parkway / I-505 Southbound Ramp Improvements
Document Type
NOD - Notice of Determination
Received
Posted
5/11/2012
Present Land Use
City & Caltrans Right-of-Way. Industrial Park, Business Park Adjacent to right of way
Document Description
The City of Vacaville proposes to construct interim improvements to the Vaca Valley Parkway / I-505 southbound ramp intersection. The interim improvements include widening of Vaca Valley Parkway west of the overcrossing to the intersection of Crocker Drive to provide a protected left turn lane for westbound traffic and a right turn lane for eastbound traffic onto the southbound I-505 on-ramp; widening of the southbound off-ramp to provide an acceleration lane for merging southbound traffic onto the I-505 from Vaca Valley Parkway; and signalization of the southbound ramp intersection with Vaca Valley Parkway.

Contact Information

Name
Tracy Rideout
Agency Name
City of Vacaville Public Works Department
Contact Types
Lead/Public Agency

Location

Cities
Vacaville
Counties
Solano
Cross Streets
Crocker Drive, Vaca Valley Parkway I-505
Zip
59688
Total Acres
2.5
Parcel #
Right of Way
State Highways
I-80 & 505
Airports
Nut Tree Airport
Waterways
Horse Creek
Township
6N
Range
1W
Section
2

Notice of Determination

Approving Agency
City Council of the City of Vacaville
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above.

Download CSV New Search Print