Upper Penitecia Creek Improvement Project

3 Documents in Project

Summary

SCH Number
2011062020
Lead Agency
Santa Clara Valley Transportation Authority
Document Title
Upper Penitecia Creek Improvement Project
Document Type
NOD - Notice of Determination
Received
Posted
8/12/2011
Present Land Use
Commercial Pedestrian & Industrial Park Zoning. Light Industrial & Combined Industrial/Commercial General Plan Designation
Document Description
The proposed project would create a creek channel sized to convey the approximate annual flood, a high-flow channel to convey sediment and water during floods greater than the annual flood, and a floodplain sized to convey the 2-year recurrence interval flood. The proposed project would realign Upper Penitencia Creek to the southwest away from commercial and residential property along the eastern edge of the creek corridor. This realignment would result in the removal of approximately 2 acres of impervious parking lot area and improve the existing highly degraded condition of the eastern and northern banks of the creek. Further, the proposed project would provide floodplain storage, remove non-native vegetation, revegetate with native wetland and riparian plantings, and enhance and restore natural creek functions and values.

Contact Information

Name
Ann Calnan
Agency Name
Santa Clara Valley Transportation Authority
Contact Types
Lead/Public Agency

Location

Cities
San Jose
Counties
Santa Clara
Cross Streets
Berryessa Road and North King Road
Zip
95132
Total Acres
3.8
Parcel #
254-17-063
State Highways
U.S. 101 and I-880
Schools
12
Waterways
Upper Penitencia Creek, Coyote Creek

Notice of Determination

Approving Agency
Santa Clara Valley Transportation Authorty
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print