Lincoln-Pleasent Grove 115 kV Reconductoring Project

2 Documents in Project

Summary

SCH Number
2011022011
Lead Agency
Regional Water Quality Control Board, Region 5 (Central Valley)
Document Title
Lincoln-Pleasent Grove 115 kV Reconductoring Project
Document Type
NOD - Notice of Determination
Received
Posted
3/10/2011

Document Description
PG&E proposes to replace approximately seven miles of an existing 60 kV power line located in southwestern Placer County between Lincoln Substation in the City of Lincoln and Pleasant Grove Substation just west of the City of Rocklin. The line will be built to 115 kV standards for conversion to, and operation at, 115 kV. The existing 95 wood poles will be replaced with a combination of wood, light duty steel (LDS), and fiberglass poles, and tubular steel poles (TSP).

Contact Information
Skyler Anderson
Regional Water Quality Control Board, Region 5 (Central Valley)
11020 Sun Center Drive, #200
Rancho Cordova, CA 95670

Phone : (916) 464-4849

Location

Coordinates
38°'21"N 121°30'"W
Cities
Lincoln
Counties
Placer
Cross Streets
Gladding Road & State Route 65
Total Acres
5.17
State Highways
Hwy 65
Schools
Lincoln HS
Waterways
Markham Ravine, Auburn Ravine, Orchard Creek
Township
11N
Range
6E
Section
9

Notice of Determination

Approving Agency
Central Valley Regional Water Quality Control Board
Approving Agency Role
Lead Agency
Approved On
Final Environmental Document Available at
11020 Sun Center Drive #200 Rancho Cordova, CA 95670

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
Yes
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print