Via Blairo Lane Sewer Main Project No. 18-206

Summary

SCH Number
2010089019
Lead Agency
City of Corona
Document Title
Via Blairo Lane Sewer Main Project No. 18-206
Document Type
NOD - Notice of Determination
Received
Posted
8/6/2010
Document Description
Installation and operation of a sewer main within Via Blairo Lane, including 884 linear ft of 8 inch Ductile Iron Pipe (DIP), with bidding option for use of Polyvinyl Chloride Pipe (PVC), and 299 linear ft of DIP concrete encased pipe, from the existing Via Blairo Lane Sewer Lift Station to Corona Avenue. Via Blairo Lane will be trenched for pipe replacement, and all roadway sections will be replaced in kind. The proposed sewer main will be placed at a varied depth of ~2 ft to 14 ft below the surface. The sewer main will provide a capacity flor of 1,782 cfs. The project also includes construction of associated facilities such as manholes. The proposed underground sewer main is to be located within the existing public right-of-way of Via Blairo Lane and within a proposed 10' wide public utility easement to be located within several residential properties (APN 122491006, 122491005, 122670047). The project proposes a permanent 10' wide public easement to accommodate the underground sewer main and a temporary easement for construction.

Contact Information

Name
Linda Bazmi
Agency Name
City of Corona Public Works Department
Contact Types
Lead/Public Agency

Location

Cities
Corona
Counties
Riverside

Notice of Determination

Approving Agency
City of Corona
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.