Paradise Irrigation District Corporation Yard Project

2 Documents in Project

Summary

SCH Number
2010062027
Lead Agency
Paradise Irrigation District
Document Title
Paradise Irrigation District Corporation Yard Project
Document Type
NOD - Notice of Determination
Received
Posted
8/24/2010
Document Description
The proposed project is the construction of a Corporation Yard Facility for Paradise Irrigation District (PID) operations on Clark Road. PID intends to construct a 4,000 sf field staff office including a training room and shower/locker facilities and a separate 6,800 sf warehouse and repair facility primarily situated on APN 053-150-195. The operations facility will include above ground fueling station, emergency electrical generator for supply to all buildings, sand and gravel storage, vehicle and equipment storage, and pipe and fittings storage. Communication conduit will be placed between the PID Administration Building and the proposed buildings. The property will be graded and sloped with retaining walls and a pipe or new drainage channel constructed to accommodate the seasonal drainage flows across the property.

Contact Information

Name
George Barber
Agency Name
Paradise Irrigation District
Contact Types
Lead/Public Agency

Location

Cities
Paradise
Counties
Butte
Cross Streets
Bille Road and Pearson Road
Zip
95969
Total Acres
4.26
Parcel #
053-150-195 & 053-012-018, 19, 20
State Highways
70, 99
Airports
Paradise Skypark
Schools
Paradise USD
Waterways
Clear Creek
Township
22N
Range
3E
Section
13
Base
MDB&M

Notice of Determination

Approving Agency
Paradise Irrigation District
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print