San Elijo Joint Powers Authority Recycled Water Expansion Improvement Project

2 Documents in Project

Summary

SCH Number
2009091078
Lead Agency
San Elijo Joint Powers Authority
Document Title
San Elijo Joint Powers Authority Recycled Water Expansion Improvement Project
Document Type
NOD - Notice of Determination
Received
Posted
2/14/2011
Present Land Use
PLU: San Elijo Water Reclamation Facility Public Utility
Document Description
The project proposes to create an additonal 600 ac ft (AF) per year of new water supply; improve water quality, reliability and operational efficiency of the recycled water produced at the facility; add treatment to allow the facility to accept and treat urban runoff; and create new opportunities to protect coastal water quality. Project improvements would include (1) constructing 0.5 MGD of advanced wastewater treatment, (2) converting an existing tank to store recycled water, (3) constructing a new recycled water distribution pumping station, (4) convert existing tanks to store treated wastewater from the Escondido Land Outfall for emergency outfall pressure equalization, and (5) construct new distribution pipelines to serve additional customers. Items 4 through 4 will be activities performed at the San Elijo Water Reclamation Facility. Item 5 would provide offsite recycled water extension pipelines along Encinitas Boulevard (from 3rd Street to Saxony Road, ~0.61 mile in length) and Paseo de Las Flores (from Quali Gardens Drive to Lynwood Drive, ~0.56 mile in length).

Contact Information

Name
Michael Thornton
Agency Name
San Elijo Joint Powers Authority
Contact Types
Lead/Public Agency

Location

Cities
Encinitas
Counties
San Diego
Cross Streets
multiple
Zip
92024
State Highways
Hwy 101
Waterways
San Elijp Lagoon

Notice of Determination

Approving Agency
San Eliio Joint Powers Authority
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.