2320 Pressure Zone, Phase II, Hillside Pump Station Expansion and Reach I Pipeline

2 Documents in Project

Summary

SCH Number
2009031024
Lead Agency
Western Municipal Water District
Document Title
2320 Pressure Zone, Phase II, Hillside Pump Station Expansion and Reach I Pipeline
Document Type
NOD - Notice of Determination
Received
Posted
4/20/2009
Present Land Use
This areas adjacent to the Hillside Pump Station site and waterline are designated as estate density residential and rural residential land uses.
Document Description
An initial study has been prepared to assess the potential for any significant environmental effects associated with the Western Municipal Water Districts (WMWD) 2329 Pressure Zone, Phase II, Hillside Pump Expansion. The purpose of the proposed project is to ensure adequate water supply and service to WMWD's customers under the South Added Facilities Area Master Plan. Phase II of the interim plan includes the expansion of the existing Hillside Pump Station. The Hillside Pump station expansion will involve the installation of four additional pumps, electrical gear, suction/discharge headers, fencing, grading, connection to existing system, abandonment of some existing pipes, and replacement of existing pumps. This phase also include the placement of approximately 1.6 miles of 30-inch waterline located on Rolling Meadows Drive.

Contact Information

Name
Thomas H Safford
Agency Name
Western Municipal Water District
Contact Types
Lead/Public Agency

Location

Counties
Riverside
Cross Streets
Rolling Meadows Drive, Jansen Road, Idaleona Road, Eldridge Drive
Zip
92570
Parcel #
Multiple
Township
4S
Range
5W
Section
23,14
Base
SBB&M
Other Location Info
City/Nearest Community: Gavilan Hills/Lake Matthews

Notice of Determination

Approving Agency
Western Municipal Water District
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print