Old Priest Grade Guardrail and Widening Project (TC08-012)

3 Documents in Project

Summary

SCH Number
2008052118
Lead Agency
Tuolumne County
Document Title
Old Priest Grade Guardrail and Widening Project (TC08-012)
Document Type
NOD - Notice of Determination
Received
Posted
11/17/2009
Present Land Use
Old Priest Grade Road
Document Description
Installation of approximately 2,500 lineal feet of metal beam guard rail (MBGR) on Old Priest Grade Road. The MBGR will be installed in two locations. Approximately 1,000 feet will be installed between Stations 45+00 and 55+00 and approximately 1,530 feet will be installed between Stations 70+00 and 85+00. MBGR will be installed on the outside of the roadway in accordance with Caltrans standard plans detail A77A1 with a minimum hinge point of two feet and type SKT end treatments per A77L2. The project will include removing some areas of existing pavement and providing new base and asphalt in those areas to accommodate minor widening of the road. The travel way will remain the same width as it currently is (20 feet). Small cuts will be made into the existing hillside and the excess material will be used to raise existing parking areas to road grade for better access. All construction is anticipated to be accomplished from the existing road with equipment such as an excavator and bulldozer. The road will be closed during construction.

Contact Information

Name
Mike Laird
Agency Name
Tuolumne County Community Development Department
Contact Types
Lead/Public Agency

Location

Counties
Tuolumne
Cross Streets
Old Priest Grade Road and State Route 120
Zip
95347
Total Acres
3.0+
Parcel #
65-140-38, 45
State Highways
SR 120
Waterways
Grizzly Creek
Township
1S
Range
16E
Section
25, 26
Base
MDB&M
Other Location Info
City/Nearest Community: Moccasin

Notice of Determination

Approving Agency
Tuolumne County, Board of Supervisors
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above.

Download CSV New Search Print