2008 Waste Water Treatment Plant Upgrades (Project); Clean Water State Revolving (CWSRF) Fund No. C-06-5179-110

11 Documents in Project

Summary

SCH Number
2007122100
Lead Agency
San Andreas Sanitary District
Document Title
2008 Waste Water Treatment Plant Upgrades (Project); Clean Water State Revolving (CWSRF) Fund No. C-06-5179-110
Document Type
NOD - Notice of Determination
Received
Posted
11/17/2008
Present Land Use
WWTF: Residential Agricultural, Public Service, Parks and Recreation, and Commercial Recreation Baker Ranch: Exclusive Agriculture Pipeline: General Ag
Document Description
The project elements consists of: 1. Construction of an administrative building and parking areas, 2. Installation of biological nitrification/activated sludge process facilities, 3. Installation of a new secondary clarifier, 4. Installation of tertiary filters with flocculation basins, 5. Modification of existing chlorination/dechlorination facilities, 6. Improvements to the facility hydraulics to incorporate the new processes, and 7. Construction of chemical storage and metering facilities.

Contact Information

Name
Lowell Jarvis
Agency Name
State Water Resources Control Board
Contact Types
Lead/Public Agency

Location

Counties
Calaveras
Cross Streets
Gold Strike Road and Gold Oak Road
Zip
95249
Total Acres
6
Parcel #
40012039, 42001004, 40012011
State Highways
49, 12, 88
Township
4N
Range
11E
Section
13
Base
MDB&M
Other Location Info
City/Nearest Community: San Andreas

Notice of Determination

Approving Agency
State Water Resources Control Board
Approving Agency Role
Responsible Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
N/A
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print