San Andreas Sanitary District Wastewater Treatment Improvement Project
10 Documents in Project
Download CSV
New Search
Print
Summary
- SCH Number
- 2007122100
- Lead Agency
- San Andreas Sanitary District
- Document Title
- San Andreas Sanitary District Wastewater Treatment Improvement Project
- Document Type
- NOD - Notice of Determination
- Received
- Posted
- 8/21/2008
- Present Land Use
- WWTF: Residential Agricultural, Public Service, Parks and Recreation, and Commercial Recreation Baker Ranch: Exclusive Agriculture Pipeline: General Ag
- Document Description
- The Project includes four main parts in four connected area. 1. The "WWTP upgrades" (treatment process improvements) will include, expansion of treatment, storage and disposal capacity to comply with regulations and accommodate new near term growth. 2. 3 new storage ponds and the excavation/expansion of existing Pond D. 3. Spray irrigation system, emergency run-off system for water collection, and ground water monitoring wells. 4. Reduced dilution ratio for surface water discharge and an extended winter discharge period.
- Contact Information
-
Steve Schimp
San Andreas Sanitary District
Lead/Public Agency
P.O. Box 1630
San Andreas, CA 95249
Phone : (209) 754-3281
Location
- Counties
- Calaveras
- Cross Streets
- Gold Strike Road and Gold Oak Road
- Zip
- 95249
- Total Acres
- 6
- Parcel #
- 40012039, 42001004, 40012011
- State Highways
- 49, 12, 88
- Township
- 4N
- Range
- 11E
- Section
- 13
- Base
- MDB&M
- Other Location Info
- City/Nearest Community: San Andreas
Notice of Determination
- Approving Agency
- San Andreas Sanitary District
- Approving Agency Role
- Lead Agency
- Approved On
- Final Environmental Document Available at
- 152 East St. Charles Street San Andreas, CA 95249
Determinations
- (1) The project will have a significant impact on the environment
- No
- (2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
- No
- (2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
- Yes
- (2c) An other document type was prepared for this project pursuant to the provisions of CEQA
- No
- (3) Mitigated measures were made a condition of the approval of the project
- Yes
- (4) A mitigation reporting or monitoring plan was adopted for this project
- N/A
- (5) A Statement of Overriding Considerations was adopted for this project
- No
- (6) Findings were made pursuant to the provisions of CEQA
- Yes
Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.