Sunol Valley Water Treatment Plant Improvement Project

6 Documents in Project

Summary

SCH Number
2007082014
Lead Agency
San Francisco, City and County of (City and County of San Francisco)
Document Title
Sunol Valley Water Treatment Plant Improvement Project
Document Type
NOD - Notice of Determination
Received
Posted
12/24/2009

Document Description
The proposed project involves the construction and operation of a new 17.5 MG treated water reservoir, 3.5 MG chlorine contact tank, flocculation and sedimentation basin, construction of new effluent pipelines within the SVWTP, and a new 78 inch pipeline connecting the new treated water reservoir to the existing 78 inch plant discharge pipeline, which transports water from the plant to the existing Alameda Siphons. The proposed project would improve treatment reliability by increasing the plant's sustainable capacity to 160 million gallons per day and bring the SVWTP in compliance with CDPH.

Contact Information
Brett Becker
San Francisco Planning Department
1650 Mission Street, Suite 400
San Francisco, CA 94103-2479

Phone : (415) 575-9045

Location

Coordinates
37°32'16.2"N 121°51'27.2"W
Cities
San Francisco
Counties
San Francisco
Cross Streets
Calaveras Rd
Zip
94586
Total Acres
94
Parcel #
096 008000602, 096 010002800
State Highways
680
Waterways
Alameda Creek
Township
4S
Range
1E
Section
34
Other Location Info
City/Nearest Community: Sunol

Notice of Determination

Approving Agency
SF City and County
Approving Agency Role
Lead Agency
Approved On
Final Environmental Document Available at
SF City and County Planning Information Center 1660 Mission St, 1st Floor San Francisco, CA 94103

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print