Feather River Levee Repair Project, an Element of the Yuba-Feather Supplemental Flood Control Project

19 Documents in Project

Summary

SCH Number
2006062071
Lead Agency
Three Rivers Levee Improvement Authority
Document Title
Feather River Levee Repair Project, an Element of the Yuba-Feather Supplemental Flood Control Project
Document Type
NOD - Notice of Determination
Received
Posted
3/21/2008
Present Land Use
Valley Agriculture, Exclusive Agricultural
Document Description
The project will correct deficiencies in the left bank levees of the Feather and lower Yuba Rivers. The project extends northward from approximately Pump Station No. 2 on the Feather River to near the SR 70 crossing of the Yuba River. The southern and northern levee segments will be strengthened in place, and a setback levee will be constructed to replace the existing middle levee segment. DWR is providing the funding for the project.

Contact Information

Name
Eric Koch
Agency Name
Dept. of Water Resources
Contact Types
Lead/Public Agency

Location

Cities
Marysville, Yuba City
Counties
Yuba
Cross Streets
State Route 70 / Feather River Boulevard
Zip
95901
State Highways
70
Railways
Western Pacific
Airports
Yuba County Airport
Schools
Alicia Intermediate and Notre Dame HS
Waterways
Yuba and Feather Rivers
Township
13-15N
Range
3E, 4E
Section
Multip
Base
MDBM

Notice of Determination

Approving Agency
Dept. of Water Resources
Approving Agency Role
Responsible Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
Yes
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
Yes
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.