Linda County Water District Wastewater Treatment Plant and River Outfall Improvements

5 Documents in Project

Summary

SCH Number
2006032130
Lead Agency
Linda County Water District
Document Title
Linda County Water District Wastewater Treatment Plant and River Outfall Improvements
Document Type
NOD - Notice of Determination
Received
Posted
7/7/2009
Present Land Use
Wastewater Treatment Plant
Document Description
The proposed project involves expanding the WWTP, upgrading the treatment level from secondary to tertiary treatment, and increasing the WWTP capacity from 1.8 million gallons per day (mgd) to 5.0 mgd. The project will involve: 1) constructing a new influent pump station, a new headworks facility, two rectangular primary clarifiers, two circular secondary clarifers, a primary sludge pump station, return activated sludge and waste activated sludge pump stations, a filter feed pump station, a compressible medium filtration system, new waste activated sludge thickening facilities, an emergency storage pond and laboratory building; 2) improving the biological treatment, sludge digestion and digested sludge dewatering processes; and 3) other site improvements.

Contact Information

Name
Lisa Lee
Agency Name
State Water Resources Control Board, Division of Financial Assis
Contact Types
Lead/Public Agency

Location

Cities
Marysville
Counties
Yuba
Zip
95901
Total Acres
15
Railways
SPRR line parallels SR 65
Airports
Yuba County Airport
Schools
Alicia Intermediate School
Waterways
Feather River, Yuba River
Township
14N
Range
3E
Section
1, 2
Base
MD
Other Location Info
Unincorporated area of Linda

Notice of Determination

Approving Agency
State Water Resources Control Board
Approving Agency Role
Responsible Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
Yes
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
Yes
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print