Mustards, Inc. Wastewater Treatment and Disposal System (Use Permit Modification #03460-UP)

2 Documents in Project

Summary

SCH Number
2005042012
Lead Agency
Napa County
Document Title
Mustards, Inc. Wastewater Treatment and Disposal System (Use Permit Modification #03460-UP)
Document Type
NOD - Notice of Determination
Received
Posted
5/31/2005
Present Land Use
Restaurant / Commercial Limited (CL) and Agricultural Preserve (AP) / Agricultural Resource
Document Description
Approval of a Use Permit Modification to (1) disestablish and dismantle parts of the current wastewater system used by Mustards Grill and the neighboring Cosentino Winery; (2) to implement the Riechers Spence prepared transition plan (third reivision, forwarded to the Regional Water Quality Control (RWQCB) via letter dated March 17, 2005) which will disconnect both parties from the current system, maintain safe treatment and disposal during construction, and ultimately reestablish flows to the new systems; (3) establish a new wastewater system for Mustards; (4) closure of pond 2 on the Mustards property; (5) processing of a minor lot line adjustment (LLA); (6) construction of a 100 sf utility building; (7) construction of a gravel road along the south side of the disposal field to provide access to the utility building; and (8) rehabilitation of an existing drainage ditch.

Contact Information

Name
Steven Lederer
Agency Name
Napa County
Contact Types
Lead/Public Agency

Location

Cities
Yountville
Counties
Napa
Cross Streets
Yount Mill Road
Total Acres
6
Parcel #
027-500-014
State Highways
29
Railways
NV Wine Train
Waterways
Napa River, unnamed stream
Township
7N
Range
5W
Section
35
Base
Diablo

Notice of Determination

Approving Agency
Napa County Conservation, Development and Planning Department
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print