Stream Alteration Agreement No. 1600-2011-0155-R4 for the Plano Street Bridge Widening Project

3 Documents in Project

Summary

SCH Number
2003051044
Lead Agency
City of Porterville
Document Title
Stream Alteration Agreement No. 1600-2011-0155-R4 for the Plano Street Bridge Widening Project
Document Type
NOD - Notice of Determination
Received
Posted
3/26/2012
Document Description
The California Department of Fish and Game is executing a Lake and Streambed Alteration Agreement pursuant to Section 1602 of the Fish and Game Code for the Plano Street Bridge Widening Project. The Project will include: Widening the existing 2-lane bridge structure, reconstructing the roadway approaches, and relocating existing utilities on the bridge. The existing bridge will be widened symmetrically about the centerline of the existing bridge structure using cast-in-place T-Girder superstructures. The width of the bridge structure will be widened from its current width of approximately 10 meters to 24.35 meters. The widened bridge will allow for two (2) travel lanes, a bike lane, and a sidewalk in each direction and will also include construction of railing and lighting. The widened bridge will have a total length of approximately 179 meters and will have four (4) abutments and 15 intermediate bents. The widened bridge and utilities will be located completely within the existing right-of-way.

Contact Information

Name
Bradley Dunlap
Agency Name
City of Porterville
Contact Types
Lead/Public Agency

Location

Cities
Porterville
Counties
Tulare
Cross Streets
Plano St. and Tule River
Zip
93257
State Highways
190
Railways
SPRR & AT&SFRR
Airports
Porterville Airport
Schools
Porterville Unified School District
Waterways
Tule River, Porter Slough, and Various Irrigation Channels

Notice of Determination

Approving Agency
CDFG
Approving Agency Role
Responsible Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
Yes
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
N/A
(6) Findings were made pursuant to the provisions of CEQA
Yes

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.