Vallejo Avenue Sewer

3 Documents in Project

Summary

SCH Number
2002101142
Lead Agency
Eastern Municipal Water District (EMWD)
Document Title
Vallejo Avenue Sewer
Document Type
NOD - Notice of Determination
Received
Posted
2/3/2003
Document Description
The existing sewer force main that crosses the 15 Freeway just north of Highway 79 South in Temecula has exceeded its useful life. The proposed sewer pipeline project includes installation of approximately 1200 lineal feet of 12" PVC below-ground gravity sewer main in place of the existing sewer force main. The sewer pipeline will be installed between the northeast corner of the intersection of Front Street and Highway 79 on the west side of the 15 Freeway and extend easterly across the Freeway to Vallejo Avenue on the east side of the Freeway. Th portion of sewer pipeline to be installed across the 15 Freeway will be bored and jacked under the Freeway through the existing steel encasing. The remaining sewer pipeline to the east and west of the Freeway will be installed by open cut. The boring will require two bore pits. The bore pit east of the 15 Freeway will be in the existing gravel parking lot on the west side of Vallejo Avenue to the north of the Community Church. On the west side of the 15 Freeway, the bore pit will be located on the northeast corner of the intersection of Front Street and Highway 79. The project will allow EMWD to continue to provide adequate and dependable sewage flow for existing customers.

Contact Information

Name
Karen Hackett
Agency Name
Eastern Municipal Water District
Contact Types
Lead/Public Agency

Location

Cities
Temecula
Counties
Riverside
Cross Streets
Front Street, Hwy 79 west of 215 Freeway
Zip
92590
Parcel #
book 922-pages 12, 13
State Highways
15, 215

Notice of Determination

Approving Agency
Eastern Municipal Water District
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
No
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.