Proposed Caltrans Annex I and II Seismic Retrofit Project

2 Documents in Project

Summary

SCH Number
2001082111
Lead Agency
California Department of Transportation, District 3
Document Title
Proposed Caltrans Annex I and II Seismic Retrofit Project
Document Type
NEG - Negative Declaration
Received
Present Land Use
Public Office C2-General Commercial
Document Description
The proposed Caltrans Annex I and II seismic retrofit project would entail structural improvements and modifications to two Caltrans buildings to reduce the seismic risk levels as prescribed under the State Building Seismic Program. The reduction of seismic risk levels can be accomplished effectively by a new lateral load resisting system, consistent with the provisions of the 1998 California Building Code. The key aspect of the proposed retrofit project is the addition of reinforced concrete shear walls on the exterior corners of the building and at the juncture of Annex I and II. The walls would extend from the basement to the roof and would replicate original architectural details and include new slightly smaller operable windows at existing window locations at all levels.

Contact Information

Name
Susan K. Stratton
Agency Name
Department of Transportation, District 3
Contact Types
Lead/Public Agency

Location

Cities
Sacramento
Counties
Sacramento
Cross Streets
11th and O Streets
Zip
95814

Notice of Completion

State Review Period Start
State Review Period End
State Reviewing Agencies
California Department of Conservation (DOC), California Department of Fish and Wildlife, North Central Region 2 (CDFW), California Department of Parks and Recreation, California Department of Transportation, District 3 (DOT), California Native American Heritage Commission (NAHC), California Regional Water Quality Control Board, Central Valley Sacramento Region 5 (RWQCB), California State Lands Commission (SLC), Central Valley Flood Protection Board, Department of General Services (DGS), Department of Toxic Substances Control, Office of Historic Preservation, Resources Agency
Development Types
Other (Seismic Retrofit)
Project Issues
Air Quality, Cultural Resources, Noise

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.