Calera Creek Floodwalls Project

4 Documents in Project

Summary

SCH Number
2001012024
Lead Agency
Santa Clara Valley Water District
Document Title
Calera Creek Floodwalls Project
Document Type
NOD - Notice of Determination
Received
Posted
5/30/2001
Present Land Use
Stream that has been modified for flood protection purposes. Zoning: I
Document Description
The California Department of Fish and Game is executing a Lake and Streambed Alteration Agreement (#R3-2001-0090) pursuant to Section 1601 of the Fish and Game Code to the project applicant, Santa Clara Valley Water District. The applicant proposes to provide maintenance access and permanent replacement of the emergency floodwall. Permanent replacement of work involves replacement of the floodwall with an 86-foot by 8-foot floodwall, removal and replacement of approximately 3,200 square feet of existing sack concrete slope protection. New construction includes an earthen levee embankment and tie-in to the existing levees and replaced floodwall; installation of a 42-foot clear span maintenance bridge at the downstream end of the Union Pacific Railroad box culvert; and installation of approximately 1,015 square feet of rock slope protection.

Contact Information

Name
Marcia Grefsrud
Agency Name
California Department of Fish and Game
Contact Types
Lead/Public Agency

Location

Cities
Milpitas
Counties
Santa Clara
Cross Streets
California Circle
Zip
95035
State Highways
880, 237
Waterways
Calera Creek

Notice of Determination

Approving Agency
California Department of Fish and Game
Approving Agency Role
Responsible Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
N/A
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
N/A
(6) Findings were made pursuant to the provisions of CEQA
N/A

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.