Placer Vineyards 4B/7 16th Street Shared Sewer #08 Project

64 Documents in Project

Summary

SCH Number
1999062020
Lead Agency
Placer County
Document Title
Placer Vineyards 4B/7 16th Street Shared Sewer #08 Project
Document Type
NOD - Notice of Determination
Received
Posted
12/24/2021
Document Description
The Project is a 5.66-acre component of the PVSP Backbone Infrastructure project, which includes the onsite infrastructure elements required for development of the PVSP. Specifically, the Project includes a sewer line and associated maintenance road. The initial phase of proposed work within the Project area will be the installation of approximately 1,600 linear feet of an 18-inch sewer line and the construction of approximately 1,605 linear feet of a 14-foot wide maintenance road. The sewer line will be constructed via an open trench. The eventual full build out of Segment L will include the construction of future South Town Drive.

Contact Information

Name
Lynn Coster
Agency Name
Central Valley Regional Water Quality Control Board
Job Title
Senior Environmental Scientist
Contact Types
Responsible Agency

Location

Cities
Roseville
Counties
Placer
Regions
Northern California
Township
10 N
Range
5 E
Section
10
Base
MDB&M

Notice of Determination

Approving Agency
Central Valley Regional Water Quality Control Board
Approving Agency Role
Responsible Agency
Approved On
County Clerk
Placer
Final Environmental Document Available at
The final EIR with comments and responses is available to the general public at: County of Placer - Placer Vineyards Specific Plan - Environmental Impact Report (https://www.placer.ca.gov/3566/Environmental-Impact-Report).

Determinations

(1) The project will have a significant impact on the environment
Yes
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
Yes
(6) Findings were made pursuant to the provisions of CEQA
Yes

Attachments

Disclaimer: The Governor’s Office of Planning and Research (OPR) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit OPR’s Accessibility Site.