Vineyard Springs Comprehensive Plan

12 Documents in Project

Summary

SCH Number
1996022060
Lead Agency
Sacramento County
Document Title
Vineyard Springs Comprehensive Plan
Document Type
NOD - Notice of Determination
Received
Posted
11/22/2013
Present Land Use
Various
Document Description
The adopted Drainage Master Plan for the Vineyard Springs Comprehensive Plan (VSCP) includes two regional detention basins at the confluence of Laguna Creek Tributary #1, two local detention basins on Laguna Creek, a single detention basin facility on Gerber Creek, and channelization of Laguna Creek from Sheldon Road to Vineyard Road (a total of five miles). The DMP also mentions that the ultimate condition will require an additional regional basin at the "Sacramento Aggregate Plant" (the Triangle Rock quarry) at a future time (noted as "20 to 25 years away" at the time the DMP was published). This ultimate basin would be located south of Florin Road in between the Folsom South Canal and Laguna Creek. The VSCP itself included plans to incorporate pedestrian and bicycle trails within the open space corridor along Laguna Creek. The goals of the adopted DMP included the elimination of what is called the "inter-basin transfer" between Laguna and Gerber Creek and the containment of the 100-year floodplain within the Laguna Creek open space corridor.

Contact Information

Name
Catherine Hack
Agency Name
Sacramento County
Contact Types
Lead/Public Agency

Location

Cities
Vineyard (subdivision)
Counties
Sacramento
Cross Streets
Vineyard Road / Calvine Road
Zip
95829
Parcel #
Various
State Highways
SR 16
Railways
Central CA
Schools
Arnold Adreani ES
Waterways
Laguna Creek
Township
7N
Range
6E
Section
9,10
Base
MDBM
Other Location Info
Vineyard

Notice of Determination

Approving Agency
County of Sacramento
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
Yes
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above. You may also contact the OPR via email at state.clearinghouse@opr.ca.gov or via phone at (916) 445-0613.

Download CSV New Search Print