Geysers Recharge Project Construction Addendum Upper and Lower Pine Flat Road Segments

19 Documents in Project

Summary

SCH Number
1994103069
Lead Agency
City of Santa Rosa
Document Title
Geysers Recharge Project Construction Addendum Upper and Lower Pine Flat Road Segments
Document Type
NOD - Notice of Determination
Received
Posted
3/29/2000
Present Land Use
Varies. Mostly rural residential and agricultural. Some industrial and business/office.
Document Description
As a result of final engineering design, minor changes to the Upper and Lower Pine Flat Road Segments of the Geysers Recharge Project have been recommended. The modifications consist of minor changes in pipeline alignments in five locations, construction of one 1-million gallon storage tank instead of 2 half million gallon tanks at the end of the transmission pipeline, changes to project description measures adopted as part of the project, and changes to mitigation measures.

Contact Information

Name
Dan Carlson
Agency Name
City of Santa Rosa
Contact Types
Lead/Public Agency

Location

Cities
Santa Rosa
Counties
Sonoma
Cross Streets
Numerous
Total Acres
130
Parcel #
Approximately 400, see Appendix F of Supplemental EIR
State Highways
101,12,16
Railways
Nothwestern Pacific
Airports
Sonoma County Airport
Waterways
Russian River, Santa Rosa Creek, Laguna de Santa Rosa
Township
6N,7N
Range
8/9W
Section
variou
Base
Mt diabl
Other Location Info
Northeast of Healdsburg: Pine Flat Road and cross-country segments extending from Pine Flat Road at Highway 128 to just north of Bear Canyon and from Pine Flat Road just below Anna Belcher Creek to the terminal tanks at the Geysers streamfield.

Notice of Determination

Approving Agency
City of Santa Rosa
Approving Agency Role
Lead Agency
Approved On

Determinations

(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
No
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
N/A
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
No

Disclaimer: The document was originally posted before CEQAnet had the capability to host attachments for the public. To obtain the original attachments for this document, please contact the lead agency at the contact information listed above.

Download CSV New Search Print