SCH Number,Lead Agency Name,Lead Agency Title,Lead Agency Acronym,Document Title,Document Type,Received,Posted,Document Description,Document Portal URL,Project Title,Contact Full Name,Contact Authority,Contact Job Title,Contact Email Address,Contact Address 1,Contact Address 2,Contact City,Contact State,Contact Zip Code,Contact Phone Number,Location Coordinates,Cities,Counties,County Clerks,Location Cross Streets,Location Zip Code,Location Total Acres,Location Parcel Number,Location State Highways,Location Waterways,Location Airports,NOC Has Non Late Comment,NOC State Review Start Date,NOC State Review End Date,NOC Development Type,NOC Local Action,NOC Project Issues,NOC Local Review Start Date,NOC Local Review End Date,NOE Exempt Status,NOE Exempt Citation,NOE Reasons for Exemption,NOD Agency,NOD Approved By Lead Agency,NOD Approved Date,NOD Significant Environmental Impact,NOD Environmental Impact Report Prepared,NOD Negative Declaration Prepared,NOD Other Document Type,NOD Mitigation Measures,NOD Mitigation Reporting Or Monitoring Plan,NOD Statement Of Overriding Considerations Adopted,NOD Findings Made Pursuant,NOD Final EIR Available Location 2020120214,"Forestry and Fire Protection, Department of",California Department of Forestry and Fire Protection,CAL FIRE,Hollister Air Attack Base Project,NOE,12/11/2020,12/11/2020,"To facilitate the arrival of a new helicopter, additional space will be leased for capital improvements and additional personnel. Capital improvements will include a helipad, parking area, two double-wide barracks trailers and a single-wide office trailer. The modular office trailer is a temporary single-story structure measuring 56 feet long by 12 feet wide. The two-modular double-wide barracks trailers measure 68 feet long by 28 feet wide. As these are modular units, no foundation will be constructed and the temporary structures will be supported by concrete footings and piers that sit atop the existing paved surface. Trenching will be completed at lineal distance of approximately 150 feet to and at a depth of 30 inches to connect a sewage pipe to the barracks. Trenches will be backfilled and compacted once the pipe is installed. The proposed helipad will be a 13,000 square feet concrete surface installed adjacent to an existing runway, taxiway and airport apron. Approximately 250 feet of trench at a depth of 30 inches will be constructed adjacent to and underneath the taxiway to supply electricity to the helipad lighting. The Proposed parking area will total approximately 0.5 acres and will be an extension of the paved area within the project. It is on disturbed soils that have been compacted and graveled. The area is currently used as a parking and storage area.",https://ceqanet.opr.ca.gov/2020120214/2,Hollister Air Attack Base Project,Christina Snow,Department of Forestry and Fire Protection,N/A,christina.snow@fire.ca.gov,1131 S Street,,Sacramento,CA,95811,9163241639,,,San Benito,,San Felipe Road,,,,,,,,,,,,,,,Categorical Exemption,"Class 3, Section 15303 New Construction or Conversion of Small Structures",The proposed new structures and improvements will be constructed on an existing active airport that is within an area that is highly disturbed. ,,,,,,,,,,,,