SCH Number,Lead Agency Name,Lead Agency Title,Lead Agency Acronym,Document Title,Document Type,Received,Posted,Document Description,Document Portal URL,Project Title,Contact Full Name,Contact Authority,Contact Job Title,Contact Email Address,Contact Address 1,Contact Address 2,Contact City,Contact State,Contact Zip Code,Contact Phone Number,Location Coordinates,Cities,Counties,County Clerks,Location Cross Streets,Location Zip Code,Location Total Acres,Location Parcel Number,Location State Highways,Location Waterways,Location Airports,NOC Has Non Late Comment,NOC State Review Start Date,NOC State Review End Date,NOC Development Type,NOC Local Action,NOC Project Issues,NOC Local Review Start Date,NOC Local Review End Date,NOE Exempt Status,NOE Exempt Citation,NOE Reasons for Exemption,NOD Agency,NOD Approved By Lead Agency,NOD Approved Date,NOD Significant Environmental Impact,NOD Environmental Impact Report Prepared,NOD Negative Declaration Prepared,NOD Other Document Type,NOD Mitigation Measures,NOD Mitigation Reporting Or Monitoring Plan,NOD Statement Of Overriding Considerations Adopted,NOD Findings Made Pursuant,NOD Final EIR Available Location 2012011033,Coachella Valley Water District,,CVWD,Avenue 60 Domestic Water Transmission Main,NOD,3/5/2012,3/5/2012,"The Avenue 60 Domestic Water Transmission Main project proposes the construction of approximately 10,000 feet of open trench and 1,350 feet of subsurface boring (using both directional boring and ""jack and bore"" methods) for a 24-inch domestic water pipeline along Avenue 60 between Polk Street and Pierce Street. Most of the pipeline will be constructed within the Avenue 60 right-of-way; subsurface boring will take place beneath the Coachella Valley Stormwater Channel (CVSC), Hwy 111, UPRR and 86S Expressway. The pipeline will connect the existing domestic water system downstream of the booster pumping station located on the Ion Exchange Treatment Plant No. 6806 (IXTP) site at the project's eastern terminus. A pressure reducing valve will be installed on the IXTP site where the pipeline connects to the existing domestic water system. The purpose of this project is to provide a more reliable domestic water service to existing and future CVWD customers in the Mecca, North Shore, and Area 23 pressure zones. This connection provides a redundant water supply to CVWD's eastern most customers and will reduce the demands on the IXTP for domestic water. In addition, the installation of the water transmission pipeline will allow CVWD to expand its domestic water service east of Polk Street and south of Airport Boulevard, providing existing and future domestic water customers with a reliable water source.",https://ceqanet.opr.ca.gov/2012011033/2,Avenue 60 Domestic Water Transmission Main,Steve Robbins,Coachella Valley Water District,N/A,,P.O. Box 1058,,Coachella,CA,92236,7603982651,,,Riverside,,Avenue 60-Polk Street to Pierce Street,92274,.5,Various,"Hwy 86, 86S, 111, 195",Coachella Valley Stormwater Channel,Thermal,,,,,,,,,,,,Board of Directors of the Coachella Valley Water District ,Yes,2/28/2012,No,No,Yes,,Yes,,,,"Coachella Valley Water District's Coachella Office 75-515 Hovley Lane East, Palm Desert, California."