SCH Number,Lead Agency Name,Lead Agency Title,Lead Agency Acronym,Document Title,Document Type,Received,Posted,Document Description,Document Portal URL,Project Title,Contact Full Name,Contact Authority,Contact Job Title,Contact Email Address,Contact Address 1,Contact Address 2,Contact City,Contact State,Contact Zip Code,Contact Phone Number,Location Coordinates,Cities,Counties,County Clerks,Location Cross Streets,Location Zip Code,Location Total Acres,Location Parcel Number,Location State Highways,Location Waterways,Location Airports,NOC Has Non Late Comment,NOC State Review Start Date,NOC State Review End Date,NOC Development Type,NOC Local Action,NOC Project Issues,NOC Local Review Start Date,NOC Local Review End Date,NOE Exempt Status,NOE Exempt Citation,NOE Reasons for Exemption,NOD Agency,NOD Approved By Lead Agency,NOD Approved Date,NOD Significant Environmental Impact,NOD Environmental Impact Report Prepared,NOD Negative Declaration Prepared,NOD Other Document Type,NOD Mitigation Measures,NOD Mitigation Reporting Or Monitoring Plan,NOD Statement Of Overriding Considerations Adopted,NOD Findings Made Pursuant,NOD Final EIR Available Location 2006048475,"Water Resources, Department of",California Department of Water Resources,DWR,"Rehabilitation of Cathodic Protection Anodes at Delta Field Division's Banks Pumping Plant, Skinner Fish Facility's Trash Boom and Rack, and Roaring River's Out",NOE,4/26/2006,4/26/2006,"This project will include designing, manufacturing, delivery and installation of new cathodic protection anodes, in order to restore and maintain anti-corrosion protection for various submerged metal pipelines, trash racks, outlet pipes and fish screen facilities. This will rehabilitate existing State Water Project mechanical and electrical appurtenances as required for maintenance of existing functions and purposes. Installation of anodes will require drilling about 12 wells approximately 12 inches in diameter to a depth varying by location but no deeper than 315 feet. All wells will be placed directly adjacent to the facilities to be protected within areas that are operational and well-maintained, and are not undisturbed native habitat. There will be no adverse environmental impacts associated with this work.",https://ceqanet.opr.ca.gov/2006048475,"Rehabilitation of Cathodic Protection Anodes at Delta Field Division's Banks Pumping Plant, Skinner Fish Facility's Trash Boom and Rack, and Roaring River's Out",Duane Cornett,"Department of Water Resources, Division of Engineering",N/A,,1416 Ninth Street,,Sacramento,CA,95814,9166535363,,"Byron, Fairfield","Contra Costa, Solano",,,,,,,,,,,,,,,,,Categorical Exemption,Section 15302,This project will reconstruct existing structures and facilities on the same sites with similar structures and equipment having the same purpose and capacity.,,,,,,,,,,,,