SCH Number,Lead Agency Name,Lead Agency Title,Lead Agency Acronym,Document Title,Document Type,Received,Posted,Document Description,Document Portal URL,Project Title,Contact Full Name,Contact Authority,Contact Job Title,Contact Email Address,Contact Address 1,Contact Address 2,Contact City,Contact State,Contact Zip Code,Contact Phone Number,Location Coordinates,Cities,Counties,County Clerks,Location Cross Streets,Location Zip Code,Location Total Acres,Location Parcel Number,Location State Highways,Location Waterways,Location Airports,NOC Has Non Late Comment,NOC State Review Start Date,NOC State Review End Date,NOC Development Type,NOC Local Action,NOC Project Issues,NOC Local Review Start Date,NOC Local Review End Date,NOE Exempt Status,NOE Exempt Citation,NOE Reasons for Exemption,NOD Agency,NOD Approved By Lead Agency,NOD Approved Date,NOD Significant Environmental Impact,NOD Environmental Impact Report Prepared,NOD Negative Declaration Prepared,NOD Other Document Type,NOD Mitigation Measures,NOD Mitigation Reporting Or Monitoring Plan,NOD Statement Of Overriding Considerations Adopted,NOD Findings Made Pursuant,NOD Final EIR Available Location 2000041047,Inland Empire Utilities Agency,,,Addendum to the Peace II Project Subsequent Environmental Impact Report,NOD,3/26/2012,3/26/2012,"One of the potential negative effects of substantial pumping of groundwater in the southern portion o f the Chino Basin in the potential to cause subsidence of the sediments that underlie this portion of the Basin. This issue was also extensively discussed in the Peace II Project Subsequent Environmental Impact Report (SEIR) and mitigation (Mitigation Measure 4.3-9 of the SEIR) is required to monitor subsidence and use adaptive management techniques to control subsidence if it is observed. To effectively monitor potential subsidence in the southern portion of the Chino Basin, the Watermaster is proposing to install a subsidence monitoring system termed an ""extensometer."" As a requirement of the Peace II Project SEIR, the ""Chino Creek Extensometer Facility"" (proposed project) is designed as a key subsidence monitoring system that will be installed under the Peace II Project SEIR. After reviewing the proposed Extensometer Facility location and potential environmental impacts, it was concluded that this proposed project could best meet compliance with the California Environmental Quality Act (CEQA) through preparation and consideration of an Addendum to the Peace II Project SEIR.",https://ceqanet.opr.ca.gov/2000041047/17,"Peace II Project, Chino Groundwater Basin",Chris Berch,Inland Empire Utilities Agency,N/A,,P.O. Box 9020,0657 Kimball Ave,Chino Hills,CA,91708,9099931600,34°04'03"N 117°32'41"W,,San Bernardino,,,,,,"60, I-15, I-10","Several: Chino, Cucamonga, San Servaine","Ontario, Chino",,,,,,,,,,,,Inland Empire Utilities Agency ,Yes,3/21/2012,No,Yes,No,,Yes,,No,,